DOI 10.1016/j.urology.2020.10.038
Clips Can be Safely Used for Vascular Control of the Renal Vessels During Laparoscopic Donor Nephrectomy.
Аннотация
OBJECTIVE
To review our experience using clips to control the renal vessels during laparoscopic donor nephrectomy (LDN) and determine the safety of this practice.
METHODS
We performed a retrospective review of patients who underwent LDN at our centre January 1, 2007-September 17, 2019. The primary outcome was the rate of complication associated with vascular control of the renal vessels, which included (1) conversion to open to manage bleeding, (2) additional procedures for bleeding, and (3) major bleeding requiring blood transfusion. Secondary outcomes included the rate of renal artery/vein clip dislodgement or crossing, change in hemoglobin, warm ischemia time and the incidence of intra-operative complications and postoperative in-hospital complications.
RESULTS
We included 503 patients who underwent LDN, of which 497 were left sided. The main renal artery was controlled with 3 titanium clips in 489 (97%) cases. The main renal vein was controlled with 2 polymer-locking clips in 478 (95%) cases. For our primary outcome, there were no conversions to open to manage bleeding, no secondary procedures due to bleeding and no major bleeding requiring blood transfusion. Additionally, there were no donor deaths. Regarding our secondary outcomes, there were 5 intraoperative events related to the titanium clips being placed on the renal artery and 1 intraoperative event related to the polymer-locking clips on the renal vein, none of which resulted in any morbidity.
CONCLUSION
Using 3 titanium clips on the renal artery and 2 polymer-locking clips on the renal vein during left LDN is safe and provides excellent vascular control.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.