Characteristics of recurrent in-stent restenosis after second- and third-generation drug-eluting stent implantation.

Shimono Hirokazu, Kajiya Takashi, Takaoka Junichiro, Miyamura Akihiro, Inoue Takafumi, Kitazono Kazunari, Ninomiya Toshiko, Atsuchi Yoshihiko, Atsuchi Nobuhiko, Ohishi Mitsuru

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In second- and third-generation drug-eluting stent (DES) era, in-stent restenosis (ISR) is not commonly seen. However, a few patients still need repeat revascularizations for recurrent ISR even after second- and third-generation DES implantation.

METHODS

From January 2012 to March 2017, 2339 lesions underwent second- and third-generation DES (Nobori, Promus Element, Resolute Integrity, Xience, Ultimaster and Synergy) implantation, of which 95 lesions (4.1%) underwent revascularization for first ISR. All lesions were divided into two groups of recurrent ISR group and non-recurrent ISR group. After successful optical coherence tomography (OCT) guided revascularization for all lesions, we investigated characteristics of recurrent ISR, and 2 years follow-up were completed.

RESULTS

The mean age was 70.8 ± 11.7 years, and 73.2% were males. Among 56 DES-ISR lesions which were assessed by OCT, recurrent ISR was seen in 33.9% (N = 19) at 2 years follow-up after revascularization for first ISR. Serum low-density lipoprotein-cholesterol (LDL-C) level was higher in recurrent ISR group compared with non-recurrent ISR group (114.1 ± 53.9 mg/dl vs. 90.9 ± 27.8 mg/dl, P = 0.04) and heterogeneous tissue pattern was more frequently found in recurrent ISR group compared with non-recurrent ISR group (63.2% vs. 27.0%, P = 0.03). Multivariate analysis identified a heterogeneous tissue pattern (odds ratio 3.71; 95% confidence interval 1.09-12.59; P = 0.03) as an independent predictor of recurrent restenosis.

CONCLUSION

Recurrent ISR of second- and third-generation DES was associated with heterogeneous tissue pattern of first ISR, and high LDL-C level was associated with recurrence.

Для цитирования: Shimono Hirokazu, Kajiya Takashi, Takaoka Junichiro, Miyamura Akihiro, Inoue Takafumi, Kitazono Kazunari, Ninomiya Toshiko, Atsuchi Yoshihiko, Atsuchi Nobuhiko, Ohishi Mitsuru. Characteristics of recurrent in-stent restenosis after second- and third-generation drug-eluting stent implantation.. Coronary artery disease. 2021. DOI: 10.1097/mca.0000000000000945.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.