Advanced operative office hysteroscopy without anaesthesia: analysis of 501 cases treated with a 5 Fr. bipolar electrode.
Аннотация
BACKGROUND
The aim of this study was to evaluate treatment efficacy and patient acceptability of a new bipolar probe used during office hysteroscopic treatment of benign intrauterine pathologies.
METHODS
In this observational clinical study, 501 women were treated for benign intrauterine pathologies using an office hysteroscopic procedure, without analgesia or anaesthesia. A Versapoint 5 Fr. bipolar electrical generator was used to treat endometrial polyps ranging between 0.5 and 4.5 cm, as well as submucosal and partially intramural myomas between 0.6 and 2.0 cm. Treatment efficacy and patient compliance were evaluated.
RESULTS
At follow-up, the uterine cavity was normal in all patients without any recurrence or persistence of the pathology. One focal adenocarcinoma was discovered at histology in an endometrial polyp of a menopausal patient. Patient acceptance was satisfactory; 47.6-79.3% of the patients underwent the procedure without discomfort.
CONCLUSIONS
The combination of a new generation small diameter hysteroscope and a new bipolar 5 Fr. electrode enables the gynaecologist to treat intrauterine pathologies in an office setting without anaesthesia. Experimentation of a special set-up of the electrical generator reduced patient discomfort during the operative part of the hysteroscopic procedure.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.