Clinical and radiographic evaluation of early loaded maxillary anterior single-tooth bone-level implants.
Аннотация
PURPOSE: The aim of this study was to evaluate the clinical and radiographic outcomes of early loaded platform-switched implants in the anterior maxilla.
MATERIALS AND
METHODS
In this study, patients were treated with implants that supported all-ceramic single-tooth crowns and were followed for 2 to 4 years. Implants were evaluated on the basis of clinical and radiographic parameters, including Plaque Index, Sulcus Bleeding Index, peri-implant probing depths (PDs), Papilla Index, soft tissue recession, and marginal bone levels. Statistical analyses were performed.
RESULTS
Fifty-five implants were placed in 47 patients. At the recall examinations, all implants had successfully integrated, demonstrating healthy peri-implant soft tissues as documented by standard clinical parameters. At the time of recall, 7 implants had been followed for 4 years, 30 implants for 3 years, and 18 implants for 2 years. Plaque accumulation scores of 2 and 3 were not noted at any point during the study. At baseline, the mean PD was 2.1 ± 0.6 mm, at 2 years it was 2.2 ± 0.6 mm, at 3 years it was 2.2 ± 0.6 mm, and at 4 years (7 implants), the mean PD was 1.9 ± 0.4 mm. There were no statistically significant differences between time intervals. Complete papilla fill was seen for 49 implants. All implants showed less than 0.5 mm of marginal bone loss; mean bone loss at the time of final recall was 0.12 ± 0.22 mm. Seven implants showed an increase in the level of bone contact. There were no statistically significant differences over time.
CONCLUSION
Bone-level implants with a platform-switched design are a successful treatment modality for anterior single-tooth implants.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.