MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultrasmedbio.2023.11.012

Медицинская библиотека · Ultrasound in medicine & biology · 2023

Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging.

Machado Priscilla, Tan Allison, Forsberg Flemming, Gonsalves Carin F

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of the work described here was to assess uterine fibroid vascularity using contrast-enhanced ultrasound (CEUS) as compared with magnetic resonance imaging (MRI).

METHODS

Forty women diagnosed with symptomatic uterine fibroids scheduled for uterine artery embolization (UAE) were enrolled in this institutional review board-approved study. Before UAE, participants underwent CEUS examination with an Aplio i800 scanner (Canon Medical Systems, Tustin, CA, USA) with curvilinear array (8C1). CEUS was performed using 2.0 mL of the ultrasound contrast agent Lumason (Bracco, Milan, Italy) administered intravenously. Digital CEUS clips were acquired and randomized offline, and fibroids were characterized as hyper- or hypovascular. MRI was used as reference standard for fibroid vascularity and compared with CEUS. Results were analyzed using McNemar's test.

RESULTS

Forty participants were enrolled in the trial. One patient did not proceed with the UAE procedure and one patient refused pre-procedure MRI because of claustrophobia. Therefore, 38 participants underwent CEUS and MRI examinations before UAE. Hypervascular fibroids were seen on MRI and CEUS in 24 and 26 participants, respectively. Hypovascular fibroids were seen with MRI and CEUS in 14 and 12 participants, respectively. Fibroids characterized as hypovascular in two participants by MRI were characterized as hypervascular by CEUS. CEUS and MRI findings were similar in 36 of 38 participants, corresponding to an accuracy of 95% (p = 0.62).

CONCLUSION

Contrast-enhanced ultrasound can accurately assess uterine fibroid vascularity, serving as a potential alternative to MRI in determination of the vascularity of uterine fibroids.

Для цитирования: Machado Priscilla, Tan Allison, Forsberg Flemming, Gonsalves Carin F. Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging.. Ultrasound in medicine & biology. 2023. DOI: 10.1016/j.ultrasmedbio.2023.11.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.