DOI 10.1038/s41598-021-02498-3

Медицинская библиотека · Scientific reports · 2021

Repeatability and reproducibility of quantitative cervical strain elastography (E-Cervix) in pregnancy.

Mlodawski Jakub, Mlodawska Marta, Plusajska Justyna, Detka Karolina, Michalska Agata, Swiercz Grzegorz, Sikorski Marek

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Strain elastography of the uterine cervix may be useful in the diagnosis and prediction of obstetric complications. The inability to obtain quantitative results, with only the possibility of visual semiquantitative evaluation of the obtained elastograms, has been the limitation of the method thus far. E-Cervix is a software program that uses intrinsic compression to excite tissue and allows the evaluation of quantitative parameters on the basis of pixel distribution in an elastogram. The aim of this study was to assess the repeatability and reproducibility of quantitative cervical strain elastography (E-Cervix) of the uterine cervix and to assess the correlation of the obtained parameters with selected clinical features of patients in the third trimester of pregnancy. In total, 222 patients participated in the study. We assessed 5 ultrasound parameters: elasticity index (ECI), hardness ratio (HR), internal os strain (IOS), external os strain (EOS) and IOS/EOS ratio. Each study was performed according to a predetermined standardized protocol. For all assessed elastographic parameters, we obtained good intra- and interobserver reproducibility. The interclass correlation coefficient (ICC) ranged from 0.77 to 0.838 for intraobserver variability and from 0.771 to 0.826 for interobserver variability. We demonstrated a significant correlation of some obtained elastographic parameters with the basic clinical features of patients, such as age, the number of previous caesarean sections, pregnancy weight and BMI. In each case, the correlation was very low. Quantitative elastographic assessment with the use of E-Cervix is characterized by good repeatability. Some clinical features may affect the value of the parameters obtained. The clinical relevance of this interference requires further investigation.

Для цитирования: Mlodawski Jakub, Mlodawska Marta, Plusajska Justyna, Detka Karolina, Michalska Agata, Swiercz Grzegorz, Sikorski Marek. Repeatability and reproducibility of quantitative cervical strain elastography (E-Cervix) in pregnancy.. Scientific reports. 2021. DOI: 10.1038/s41598-021-02498-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.