MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2009.08.012

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2009

Fluoroscopically guided percutaneous jejunostomy with use of a 21-gauge needle: a prospective study in 51 patients.

Hu Hong-Tao, Shin Ji Hoon, Song Ho-Young, Kim Jin Hyoung, Yoon Hyun-Ki, Gwon Dong-Il, Ko Gi-Young, Sung Kyu-Bo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the safety and clinical efficacy of fluoroscopically guided percutaneous jejunostomy with use of a 21-gauge needle and a single anchor technique in 51 patients.

MATERIALS AND

METHODS

From November 2006 to January 2009, 51 consecutive patients (42 men and nine women; mean age, 63.7 years) underwent percutaneous jejunostomy under fluoroscopic guidance. A 7.5-F multifunctional coil catheter was used to insufflate the jejunum. The distended jejunum was punctured with a 21-gauge needle, with the inserted coil catheter as the target. A single anchor was used. The technical success, number of punctures, procedure time, complications, and follow-up data including 30-day mortality rate were evaluated.

RESULTS

The technical success rate was 100%, and the single anchor technique was used in all but one patient, in whom three anchors were used. The mean number of punctures was 1.7 (range, 1-4), and the mean procedure time was 14.8 minutes (range, 7-29 min). Peritonitis was a major complication in two patients (3.9%), who were treated by changing the catheters from 14 F to 16 F and performing percutaneous drainage procedures. Three minor complications were encountered: superficial cellulitis (n = 2) and severe puncture site pain (n = 1). The 30-day mortality rate was 5.9% (three of 51), although none of the deaths could be attributed to the jejunostomy procedures.

CONCLUSIONS

Fluoroscopically guided percutaneous jejunostomy with use of a 21-gauge needle and the single anchor technique seems to be safe and effective, with high technical success and low complication rates.

Для цитирования: Hu Hong-Tao, Shin Ji Hoon, Song Ho-Young, Kim Jin Hyoung, Yoon Hyun-Ki, Gwon Dong-Il, Ko Gi-Young, Sung Kyu-Bo. Fluoroscopically guided percutaneous jejunostomy with use of a 21-gauge needle: a prospective study in 51 patients.. Journal of vascular and interventional radiology : JVIR. 2009. DOI: 10.1016/j.jvir.2009.08.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.