MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jon.13154

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2023

Computed tomography perfusion software pipelines to assess parameter maps and ischemic volumes: A comparative study.

Lu Wei, Yao Feirong, Yin Congguo, Wan Shu, Liu Xin, He Chongxin, Leng Xiaochang, Fiehler Jens, Siddiqui Adnan H, Peng Ya, Xiang Jianping

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: This study was dedicated to investigating the agreement of the calculated results of two CT perfusion (CTP) postprocessing software packages, including parameter maps and ischemic volume, focusing on the infarct core volume (ICV) and penumbra volume (PV).

METHODS

A retrospective collection of 235 patients with acute ischemic stroke who underwent CTP examination were enrolled. All images had been analyzed with two software pipelines, RAPID CTP and AccuCTP, and the comparative analysis was based on ICV and PV results calculated by both software packages. The agreement of parameter maps was evaluated by root mean square error and Bland-Altman analysis. The ICV and PV agreement was evaluated by intraclass correlation coefficient (ICC) and Bland-Altman analysis. The accuracy of ICV and PV based on multiple thresholds was also analyzed.

RESULTS

The ICV and PV of AccuCTP and RAPID CTP show excellent agreement. The relative differences of the parameter maps were all within 10% and the Bland-Altman analysis also showed a strong agreement. From ordinary least squares fitting results, both ICV and PV had a remarkably high goodness of fit (ICV, R2 = 0.975 [p<.001]; PV, R2 = 0.964 [p<.001]). For the ICC analysis, both had high ICC scores (ICV ICC 0.984, 95% CI [confidence interval] 0.973-0.989; PV ICC 0.955, 95% CI 0.947-0.964). Furthermore, multi-threshold analysis on the basis of ICV and PV also achieved reliable analytical accuracy.

CONCLUSIONS

The image analysis results of AccuCTP are in excellent agreement with RAPID CTP and can be used as an alternative analysis tool to RAPID CTP software in stroke clinical practice.

Для цитирования: Lu Wei, Yao Feirong, Yin Congguo, Wan Shu, Liu Xin, He Chongxin, Leng Xiaochang, Fiehler Jens, Siddiqui Adnan H, Peng Ya, Xiang Jianping. Computed tomography perfusion software pipelines to assess parameter maps and ischemic volumes: A comparative study.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2023. DOI: 10.1111/jon.13154.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.