MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10157-024-02565-9

Медицинская библиотека · Clinical and experimental nephrology · 2024

Predictors of encapsulated peritoneal sclerosis in patients undergoing peritoneal dialysis using neutral-pH dialysate.

Nakano Toshiaki, Kitamura Hiromasa, Tsuneyoshi Shoji, Tsuchimoto Akihiro, Torisu Kumiko, Tsujikawa Hiroaki, Kawanishi Hideki, Tsuruya Kazuhiko, Kitazono Takanari

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Encapsulated peritoneal sclerosis (EPS) is a serious complication in patients undergoing peritoneal dialysis (PD). Neutral-pH dialysate is associated with less peritoneal damage and a lower incidence of EPS than conventional PD solution. However, monitoring for peritoneal damage and predicting EPS remain important during PD therapy.

METHODS

We measured the mesothelial cell area, dialysate-to-plasma ratio of creatinine after 4 h, and concentrations of the potential biological markers effluent fibrin degradation products (eFDPs), cancer antigen-125, and interleukin-6 in the effluent dialysate from patients who had been undergoing PD therapy for > 5 years in our hospital. These biomarkers were obtained from the drainage fluid of the final measurement of peritoneal equilibration testing before withdrawal from PD therapy. The concentrations of these potential biomarkers were measured in 39 patients who withdrew from PD therapy and were enrolled in the study.

RESULTS

Three participants developed EPS after withdrawing PD. The dialysate-to-plasma ratio of creatinine, area of mesothelial cells, and interleukin-6 appearance rate in participants who developed EPS tended to be higher than those in patients who did not, but there were no significant differences. Significantly more eFDPs were in participants who developed EPS than in those who did not (138.5 ± 15.1 vs. 32.9 ± 7.4 µg/mL, P = 0.002). There was no difference in the cancer antigen-125 appearance rate between the groups. A cut-off value of eFDPs ≥ 119.1 µg/mL was optimal for predicting EPS (P = 0.006, specificity = 0.972, sensitivity = 1.000).

CONCLUSION

This study shows that eFDPs may be a useful biological marker for predicting EPS in patients undergoing PD using neutral-pH dialysate.

Для цитирования: Nakano Toshiaki, Kitamura Hiromasa, Tsuneyoshi Shoji, Tsuchimoto Akihiro, Torisu Kumiko, Tsujikawa Hiroaki, Kawanishi Hideki, Tsuruya Kazuhiko, Kitazono Takanari. Predictors of encapsulated peritoneal sclerosis in patients undergoing peritoneal dialysis using neutral-pH dialysate.. Clinical and experimental nephrology. 2024. DOI: 10.1007/s10157-024-02565-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.