Patient's weight-based indocyanine green dose for fluorescence angiography with led imaging system in left-sided colorectal resections.

Baldari Ludovica, Porretta Francesco, Cassinotti Elisa, Boni Luigi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

One limitation of indocyanine green (ICG) fluorescence angiography (FA) is that, following intravenous administration, the dye produces residual background fluorescence impeding accurate perfusion assessment if a second injection is required. This study aimed to identify the optimal patient weight-based ICG dose able to create a strong fluorescent signal at the level of descending colon transection and, at the same time, to ensure none or minimal background fluorescence before second FA for perfusion assessment of colorectal anastomosis.

METHODS

The first part of the study was used to define the ideal ICG doses, for overlay mode and monochromatic mode, to perform FA through the bisection method. In the second part of the study, the two doses were tested in 40 consecutive left-sided colorectal resections each, using an LED fluorescence system. Fluorescence intensity was assessed subjectively by a dose-blinded surgeon and objectively using image analysis software at three time points: after first ICG injection to identify descending colon transection line; before second injection, to define background fluorescence; after second injection, to define colorectal anastomosis fluorescence intensity.

RESULTS

Sixteen patients were included in the first part of the study and 80 patients in the second one. The ICG doses equal to 0.027 mg/kg, for overlay mode, and 0.0108 mg/kg, for monochromatic mode, are associated with medium-to-maximum subjective and objective signal intensity during perfusion assessment of both descending colon, during transection line identification, and colorectal anastomosis. Background fluorescence was assessed a median of 19 (9-90 overlay, 10-96 monochromatic subgroups) minutes after dye injection, showing no recognizable fluorescence in overlay subgroup and minimal fluorescence in monochromatic subgroup.

CONCLUSION

ICG doses calculated at 0.027 mg/kg, for overlay mode, and 0.0108 mg/kg, for monochromatic mode allow ideal intraoperative visualization during perfusion assessment of left-sided colorectal resections with ICG FA using an LED system.

Для цитирования: Baldari Ludovica, Porretta Francesco, Cassinotti Elisa, Boni Luigi. Patient's weight-based indocyanine green dose for fluorescence angiography with led imaging system in left-sided colorectal resections.. Surgical endoscopy. 2026. DOI: 10.1007/s00464-026-13267-6.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.