DOI 10.1177/1051228404273820

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2005

Reversible posterior leukoencephalopathy, cerebral vasoconstriction, and strokes after intravenous immune globulin therapy in guillain-barre syndrome.

Burns Suzanne M, Carpenter Richard, Blevins Cheri, Bragg Sharon, Marshall Mary, Browne Liz, Perkins Martha, Bagby Rebecca, Blackstone Kris, Truwit Jonathon D

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In the medical intensive care unit at the University of Virginia Health System, capnography is used to detect end-tidal carbon dioxide to protect patients from inadvertent airway cannulation during placement of gastric tubes.

OBJECTIVES

To compare the method in which capnography is used with a method in which a colorimetric carbon dioxide detector is used and to determine what variables affect accurate placement of gastric tubes.

METHODS

A prospective convenience sample of 195 gastric tube insertions was studied in 130 adult patients in a medical intensive care unit. Standard insertions of gastric tubes (done with capnography) were simultaneously monitored by using a disposable colorimetric device, with a color change indicating the presence of carbon dioxide.

RESULTS

Insertion variables included tube type (60% Salem sump tubes, 40% soft-bore feeding tubes), route of insertion (71% oral, 29% nasal), mechanical ventilation (81%), and decreased mental status (72%). Carbon dioxide was successfully detected with the colorimetric indicator (within seconds) in all insertions in which carbon dioxide was detected by capnography. When carbon dioxide was detected (27% of insertions), the tubes were withdrawn and reinserted. Carbon dioxide detection during tube placement was significantly associated with nasal insertions (P = .03) and spontaneously breathing/nonintubated status (P = .01) but not with mental status or tube type.

CONCLUSIONS

A colorimetric device is as accurate as capnography for detecting carbon dioxide during placement of gastric tubes.

Для цитирования: Burns Suzanne M, Carpenter Richard, Blevins Cheri, Bragg Sharon, Marshall Mary, Browne Liz, Perkins Martha, Bagby Rebecca, Blackstone Kris, Truwit Jonathon D. Reversible posterior leukoencephalopathy, cerebral vasoconstriction, and strokes after intravenous immune globulin therapy in guillain-barre syndrome.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2005. DOI: 10.1177/1051228404273820.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.