m+Medelevator.RU
← Поиск публикаций
Clinical imaging · 2025

Evaluating ChatGPT's performance across radiology subspecialties: A meta-analysis of board-style examination accuracy and variability.

СтатьяМетаанализНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nguyen Dan, Kim Grace Hyun J, Bedayat Arash

Аннотация

INTRODUCTION: Large language models (LLMs) like ChatGPT are increasingly used in medicine due to their ability to synthesize information and support clinical decision-making. While prior research has evaluated ChatGPT's performance on medical board exams, limited data exist on radiology-specific exams especially considering prompt strategies and input modalities. This meta-analysis reviews ChatGPT's performance on radiology board-style questions, assessing accuracy across radiology subspecialties, prompt engineering methods, GPT model versions, and input modalities.

METHODS: Searches in PubMed and SCOPUS identified 163 articles, of which 16 met inclusion criteria after excluding irrelevant topics and non-board exam evaluations. Data extracted included subspecialty topics, accuracy, question count, GPT model, input modality, prompting strategies, and access dates. Statistical analyses included two-proportion z-tests, a binomial generalized linear model (GLM), and meta-regression with random effects (Stata v18.0, R v4.3.1).

RESULTS: Across 7024 questions, overall accuracy was 58.83 % (95 % CI, 55.53-62.13). Performance varied widely by subspecialty, highest in emergency radiology (73.00 %) and lowest in musculoskeletal radiology (49.24 %). GPT-4 and GPT-4o significantly outperformed GPT-3.5 (p < .001), but visual inputs yielded lower accuracy (46.52 %) compared to textual inputs (67.10 %, p < .001). Prompting strategies showed significant improvement (p < .01) with basic prompts (66.23 %) compared to no prompts (59.70 %). A modest but significant decline in performance over time was also observed (p < .001).

DISCUSSION: ChatGPT demonstrates promising but inconsistent performance in radiology board-style questions. Limitations in visual reasoning, heterogeneity across studies, and prompt engineering variability highlight areas requiring targeted optimization.

Предметные рубрики MeSH