Computed Tomography Perfusion and Angiography for Death by Neurologic Criteria.

Chassé Michaël, Shankar Jai Jai Shiva, Fergusson Dean A, English Shane W, Dhanani Sonny, Lauzier François, Turgeon Alexis F, Ball Ian, Darvesh Sultan, Neves Briard Joel, Essig Marco, Boucher-Roy David, Titova Polina, Lebrasseur Martine, Couillard Philippe, Kramer Andreas, D'Aragon Frédérick, Hannouche Mathew, Tampieri Donatella, Meade Maureen O, Menon Bijoy K, Green Robert, Baker Andrew J, Burns Karen E A, Zarychanski Ryan, Shahin Jason, Boyd J Gordon, Binnie Alexandra, Gibson Andrew, Wang Han Ting, Shemie Sam, INDex InvestigatorsCanadian Critical Care Trials Group

Оценочное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

IMPORTANCE

Accurate and timely confirmation of death by neurologic criteria (DNC) is essential for clinical decision-making and organ-donation processes, yet currently available ancillary tests have suboptimal diagnostic performance or limited validation.

OBJECTIVES

To determine the diagnostic accuracy, interrater reliability, and safety of brain computed tomography (CT) perfusion and CT angiography as ancillary investigations for DNC.

DESIGN, SETTING, AND

PARTICIPANTS

Between April 25, 2017, and March 10, 2021, a prospective, multicenter, blinded diagnostic accuracy cohort study was conducted in 15 adult intensive care units across Canada. Consecutive, critically ill adults (aged ≥18 years) with a Glasgow Coma Scale score of 3 and no confounding factors who were at high risk of DNC were included. Data collection and analysis were performed from April 2021 to July 2024.

EXPOSURE: Contrast-enhanced brain CT perfusion with CT angiography reconstructions performed within 2 hours of a blinded, standardized clinical DNC examination.

MAIN OUTCOMES AND MEASURES: The primary outcomes were the sensitivity and specificity of qualitative and quantitative brainstem CT perfusion for DNC determination, assessed by 2 independent neuroradiologists blinded to clinical findings; the prespecified validation threshold was greater than 98%. Secondary outcomes were the diagnostic accuracy of whole-brain CT perfusion and CT angiography, interrater reliability (Cohen κ), and adverse events associated with imaging.

RESULTS

A total of 282 patients (mean [SD] age, 57.8 [15.4] years; 133 [47%] female) completed the study protocol and were included in the primary analysis; 204 (72%) of these were ultimately declared deceased by standardized clinical criteria. Qualitative brainstem CT perfusion showed a sensitivity of 98.5% (95% CI, 95.8%-99.7%) and a specificity of 74.4% (95% CI, 63.2%-83.6%); quantitative brainstem CT perfusion was not diagnostically accurate. Qualitative whole-brain CT perfusion yielded a sensitivity of 93.6% (95% CI, 89.3%-96.6%) and a specificity of 92.3% (95% CI, 84.0%-97.1%). CT angiography sensitivity ranged from 75.5% (95% CI, 69.0%-81.2%) to 87.3% (95% CI, 81.9%-91.5%), and its specificity ranged from 89.7% (95% CI, 80.8%-95.5%) to 91.0% (95% CI, 82.4%-96.3%). Interrater reliability was excellent for all ancillary tests (κ ranged from 0.81 [95% CI, 0.73-0.89] to 0.84 [95% CI, 0.78-0.91]). Fourteen patients (5%) experienced minor, self-limited adverse events; no serious adverse events occurred.

CONCLUSIONS AND RELEVANCE: The observed sensitivity and specificity measures for CT perfusion and CT angiography as an ancillary test for DNC did not meet the prespecified validation threshold of greater than 98%. Clinical examination remains the cornerstone of DNC, and ancillary imaging should be interpreted cautiously within a comprehensive clinical assessment.

Для цитирования: Chassé Michaël, Shankar Jai Jai Shiva, Fergusson Dean A, English Shane W, Dhanani Sonny, Lauzier François, Turgeon Alexis F, Ball Ian, Darvesh Sultan, Neves Briard Joel, Essig Marco, Boucher-Roy David, Titova Polina, Lebrasseur Martine, Couillard Philippe, Kramer Andreas, D'Aragon Frédérick, Hannouche Mathew, Tampieri Donatella, Meade Maureen O, Menon Bijoy K, Green Robert, Baker Andrew J, Burns Karen E A, Zarychanski Ryan, Shahin Jason, Boyd J Gordon, Binnie Alexandra, Gibson Andrew, Wang Han Ting, Shemie Sam, INDex InvestigatorsCanadian Critical Care Trials Group. Computed Tomography Perfusion and Angiography for Death by Neurologic Criteria.. JAMA neurology. 2025. DOI: 10.1001/jamaneurol.2025.2375.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.