MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-025-05050-3

Медицинская библиотека · Abdominal radiology (New York) · 2025

Evaluation of artificial-intelligence-based liver segmentation and its application for longitudinal liver volume measurement.

Kimura Rina, Hirata Kenji, Tsuneta Satonori, Takenaka Junki, Watanabe Shiro, Abo Daisuke, Kudo Kohsuke

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Accurate liver-volume measurements from CT scans are essential for treatment planning, particularly in liver resection cases, to avoid postoperative liver failure. However, manual segmentation is time-consuming and prone to variability. Advancements in artificial intelligence (AI), specifically convolutional neural networks, have enhanced liver segmentation accuracy. We aimed to identify optimal CT phases for AI-based liver volume estimation and apply the model to track liver volume changes over time. We also evaluated temporal changes in liver volume in participants without liver disease.

METHODS

In this retrospective, single-center study, we assessed the performance of an open-source AI-based liver segmentation model previously reported, using non-contrast and dynamic CT phases. The accuracy of the model was compared with that of expert radiologists. The Dice similarity coefficient (DSC) was calculated across various CT phases, including arterial, portal venous, and non-contrast, to validate the model. The model was then applied to a longitudinal study involving 39 patients without liver disease (527 CT scans) to examine age-related liver volume changes over 5 to 20 years.

RESULTS

The model demonstrated high accuracy across all phases compared to manual segmentation. Among the CT phases, the highest DSC of 0.988 ± 0.010 was in the arterial phase. The intraclass correlation coefficients for liver volume were also high, exceeding 0.9 for contrast-enhanced phases and 0.8 for non-contrast CT. In the longitudinal study, the model indicated an annual decrease of 0.95%.

CONCLUSION

This model provides high accuracy in liver segmentation across various CT phases and offers insights into age-related liver volume reduction. Measuring changes in liver volume may help with the early detection of diseases and the understanding of pathophysiology.

Для цитирования: Kimura Rina, Hirata Kenji, Tsuneta Satonori, Takenaka Junki, Watanabe Shiro, Abo Daisuke, Kudo Kohsuke. Evaluation of artificial-intelligence-based liver segmentation and its application for longitudinal liver volume measurement.. Abdominal radiology (New York). 2025. DOI: 10.1007/s00261-025-05050-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.