Performance of middle cerebral artery doppler for prediction of recurrent fetal anemia.

Oakes Megan C, O'Donnell Carly M, Zhang Fan, Bruno Ann M, Rosenbloom Joshua I, Raghuraman Nandini

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the predictive value of middle cerebral artery Doppler peak systolic velocity (MCA-PSV) for moderate-severe fetal anemia following one intrauterine transfusion (IUT) and test the performance of alternate cutoffs to the recommended threshold ≥1.69 multiples of the median (MoM).

METHODS

This was a retrospective cohort study of patients with pregnancies affected by alloimmunization who underwent percutaneous umbilical blood sampling (PUBS) procedures from 2000 to 2020. An MCA-PSV ≥1.69 MoM was the indication for the second IUT. The primary outcome was recurrent moderate-severe fetal anemia. Receiver-operating characteristic (ROC) curves assessed the predictive ability of MCA-PSV for the primary outcome and the Youden index identified the "optimal" cutoff value. Predictive characteristics of MCA-PSV ≥1.69 MoM and the "optimal" cutoff were compared.

RESULTS

Of the 58 patients who underwent IUT during the study period, 36 (62%) did not meet inclusion criteria. Of the remaining 22 patients who underwent a second PUBS, 12 (54.6%) fetuses had moderate or severe anemia. Following one IUT, the AUC for MCA-PSV was 0.86 (95% CI 0.70-1.00) for the primary outcome. The "optimal" cutoff MCA-PSV value was 1.74 MoM, which had a greater specificity than ≥1.69 MoM (90 vs. 50%, p = .05), but was not statistically significant. The sensitivity was similar between the two cutoff values of ≥1.69 and ≥1.74 MoM (83.3 vs. 75.0%, p = .65) (Table 2).

CONCLUSION

Raising the recommended MCA-PSV cutoff to ≥1.74 MoM for recurrent moderate-severe fetal anemia after one IUT would decrease the number of unnecessary procedures without significantly changing the sensitivity of this screening test.

Для цитирования: Oakes Megan C, O'Donnell Carly M, Zhang Fan, Bruno Ann M, Rosenbloom Joshua I, Raghuraman Nandini. Performance of middle cerebral artery doppler for prediction of recurrent fetal anemia.. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2021. DOI: 10.1080/14767058.2021.1967316.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.