MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/nano13091539

Медицинская библиотека · Nanomaterials (Basel, Switzerland) · 2023

Shoe-Integrated Sensor System for Diagnosis of the Concomitant Syndesmotic Injury in Chronic Lateral Ankle Instability: A Prospective Double-Blind Diagnostic Test.

Li Yanzhang, Guo Rui, Wang Yuchen, Ma Jingzhong, Miao Xin, Yang Jie, Zhang Zhu, Wu Xiaoming, Ren Tianling, Jiang Dong

СтатьяПеревод пока не подготовлен

Аннотация

Chronic lateral ankle instability (CLAI) is commonly secondary to prior lateral ankle ligament injury, and the concomitant latent syndesmosis injury would prolong recovery time and increase the risk of substantial traumatic arthritis. However, differentiating syndesmotic injury from isolated lateral ankle ligament injury in CLAI cases is difficult by conventional physical and radiological examinations. To improve the accuracy of syndesmotic injury diagnosis, a shoe-integrated sensor system (SISS) is proposed. This system measures plantar pressure during walking to detect the presence of syndesmotic injury. The study included 27 participants who had ankle sprains and underwent an examination. Plantar pressure in eight regions of interest was measured for both limbs, and syndesmotic injuries were examined using arthroscopy. The width of the syndesmosis was measured to evaluate its severity. The characteristics of plantar pressure were compared between patients with normal and injured syndesmosis. The results indicated that peak plantar pressure ratios with logistic regression predicted value > 0.51 accurately distinguished concomitant syndesmotic injury during walking, with high sensitivity (80%) and specificity (75%). The post-test probability of having a syndesmotic injury was positively 80% and negatively 25%. These findings demonstrate the effectiveness of cost-effective wearable sensors in objectively diagnosing concomitant syndesmotic injuries in cases of CLAI.

Для цитирования: Li Yanzhang, Guo Rui, Wang Yuchen, Ma Jingzhong, Miao Xin, Yang Jie, Zhang Zhu, Wu Xiaoming, Ren Tianling, Jiang Dong. Shoe-Integrated Sensor System for Diagnosis of the Concomitant Syndesmotic Injury in Chronic Lateral Ankle Instability: A Prospective Double-Blind Diagnostic Test.. Nanomaterials (Basel, Switzerland). 2023. DOI: 10.3390/nano13091539.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.