Effect of manipulating the vergence/accommodation and image size mismatches of the ±2D flipper test on the frequency and precision of accommodative facility.

Vera Jesús, Redondo Beatriz, Martínez-Tovar José Miguel, Molina Rubén, Koulieris George A, Allen Peter M, Jiménez Raimundo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The ±2.00 D accommodative facility test presents several limitations, including the lack of objective information and inherent characteristics such as vergence/accommodative conflict, change in apparent size of the image, subjective criteria for judging blur and motor reaction time. By using free-space viewing conditions and an open-field autorefractor to monitor the refractive state, we examined the impact of manipulating these factors on the qualitative and quantitative assessment of accommodative facility.

METHODS

Twenty-five healthy young adults (24.5 ± 4.5 years) took part in this study. Participants performed three accommodative facility tests (adapted flipper, 4D free-space viewing and 2.5D free-space viewing) under both monocular and binocular conditions in random order. A binocular open-field autorefractor was used to assess the accommodative response continuously, and these data were used to characterise accommodative facility quantitatively and qualitatively.

RESULTS

There were statistically significant differences between the three testing methods both quantitatively (p < 0.001) and qualitatively (p = 0.02). For the same accommodative demand, a lower number of cycles was obtained for the adapted flipper condition in comparison with the 4D free-space viewing test (corrected p-value < 0.001, Cohen's d = 0.78). However, this comparison did not reach statistical significance for qualitative measures of accommodative facility (corrected p-value = 0.82, Cohen's d 0.05).

CONCLUSIONS

These data provide evidence that the qualitative assessment of accommodative facility is not influenced by the inherent limitations of the ±2.00 D flipper test. The use of qualitative outcomes by incorporating an open-field autorefractor allows examiners to increase the validity of the accommodative facility test in both clinical and research settings.

Для цитирования: Vera Jesús, Redondo Beatriz, Martínez-Tovar José Miguel, Molina Rubén, Koulieris George A, Allen Peter M, Jiménez Raimundo. Effect of manipulating the vergence/accommodation and image size mismatches of the ±2D flipper test on the frequency and precision of accommodative facility.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2023. DOI: 10.1111/opo.13136.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.