Relationship Between Optical Coherence Tomography and Anterior Chamber Depth After Pupillary Dilation in Primary Angle Closure Suspects.

Kao Brandon Wei-Hsiang, Yonamine Sean, Zhao Mengya, Oatts Julius, Yu Yinxi, Ying Gui-Shuang, Xu Xun, Han Ying

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

PRCIS: Anterior chamber depth (ACD) change after pupillary dilation is correlated with lens vault (LV) and anterior chamber width (ACW), as observed by swept-source optical coherence tomography (SS-OCT) at both horizontal and vertical scans in patients with primary angle closure suspect and cataract.

PURPOSE: The purpose of this study is to evaluate the association between ACD and other anterior chamber parameters after pharmacological dilation in patients with primary angle closure suspect and cataract.

PATIENTS AND

METHODS

SS-OCT was performed for 78 patients at baseline and 1 hour after pharmacological dilation. Measurements were taken at 8 evenly spaced axes at 250, 500, and 750 μm from the scleral spur. Pearson correlation coefficient (ρ) was used to evaluate the relationship between averaged ACD change and other SS-OCT parameters. Multivariable regression analyses were performed to determine the parameters that predict ACD change.

RESULTS

Across all 14 dimension and angle parameters, 12 parameters at the 270-degree axis and 10 parameters at the 0-degree axis yielded significant correlations with ACD change (ρ=0.24-0.55, P <0.05). Angle parameters were most significantly correlated to ACD change 750 µm from the scleral spur. The prediction model for ACD change after pharmacological dilation at 0 degree included decreased LV, wider ACW, and increased trabecular iris space area (all P ≤0.001). The prediction model for ACD change at 270 degrees included: decreased LV, wider ACW, larger change in anterior chamber volume, larger baseline anterior chamber volume, and smaller baseline angle opening distance (all P ≤0.03).

CONCLUSIONS

LV and ACW, as measured in both vertical and horizontal scans, were found to be determinants of the ACD change after pharmacological pupillary dilation. Examination of these parameters may help identify patients at higher risk of developing angle-closure disease.

Для цитирования: Kao Brandon Wei-Hsiang, Yonamine Sean, Zhao Mengya, Oatts Julius, Yu Yinxi, Ying Gui-Shuang, Xu Xun, Han Ying. Relationship Between Optical Coherence Tomography and Anterior Chamber Depth After Pupillary Dilation in Primary Angle Closure Suspects.. Journal of glaucoma. 2022. DOI: 10.1097/ijg.0000000000002085.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.