MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11999-011-1922-y

Медицинская библиотека · Clinical orthopaedics and related research · 2011

A minimally invasive stabilizing system for dorsal pelvic ring injuries.

Dienstknecht Thomas, Berner Arne, Lenich Andreas, Nerlich Michael, Fuechtmeier Bernd

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Open reduction and stabilization of dorsal pelvic ring injuries is accompanied by a high rate of soft tissue complications. Minimally invasive techniques have the potential to decrease soft tissue trauma, but the risk of iatrogenic nerve and vessel damage through the reduced surgical exposure should be considered. We treated these injuries using a transiliac internal fixator (TIFI) in a minimally invasive technique characterized by implantation of a pedicle screw and rod system, bridging the sacroiliac joints and the sacral area.

QUESTIONS/PURPOSES: We asked whether (1) we could achieve anatomic restoration with the device, (2) specific complications were associated with this minimally invasive approach (particularly enhanced intraoperative blood loss, soft tissue complications, and iatrogenic neurovascular damage), and (3) function 3 years after trauma was comparable to that of established methods.

METHODS

We retrospectively reviewed 67 patients with dorsal pelvic injuries during a 7-year period. We evaluated the (1) reduction by grading the maximal displacement measured with three radiographic views, (2) the complications during the observation period, and (3) the function with a validated questionnaire (Pelvic Outcome Score) in all but five patients at least 3 years after trauma (mean, 37 months; range, 36-42 months).

RESULTS

At last followup we observed a secondary fracture displacement greater than 5 mm in one patient. The intraoperative blood loss was less than 50 mL in all patients. No neurovascular lesions occurred owing to implantation. Four patients had wound infections, one had loosening of a single pedicle screw, and one had an iatrogenic screw malpositioning. Thirty-five of the 62 patients achieved Pelvic Outcome Scores of either a maximum score or 6 of 7 points.

CONCLUSION

Our observations suggest TIFI is a reasonable alternative to other established fixation devices for injuries of the dorsal pelvic ring with minor risks of major blood loss or iatrogenic neurovascular damage.

LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Для цитирования: Dienstknecht Thomas, Berner Arne, Lenich Andreas, Nerlich Michael, Fuechtmeier Bernd. A minimally invasive stabilizing system for dorsal pelvic ring injuries.. Clinical orthopaedics and related research. 2011. DOI: 10.1007/s11999-011-1922-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.