MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s41824-021-00106-1

Медицинская библиотека · European journal of hybrid imaging · 2021

68Ga-FAPI-04 PET/MR is helpful in differential diagnosis of pancreatitis from pancreatic malignancy compared to 18F-FDG PET/CT: a case report.

Shou Yi, Xue Qiaoyi, Yuan Jianmin, Zhao Jun

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

68Ga-fibroblast activation protein-specific enzyme inhibitor 04 (FAPI-04) is a radiolabelled molecular agent targeting the inhibitor of fibroblast activation protein (FAP), which is often present in tumor stroma and inflammatory tissue with prominent fibroblast proliferation. FAPI-04 is a promising PET tracer for tumor imaging as well as IgG4-related disease (IgG4-RD).

CASE DESCRIPTION: We herein present a case where 68Ga-FAPI PET/MR helped to diagnose IgG4-RD that involved pancreas and bile duct. A 62-year-old patient suffered from diffusive discomfort at middle upper abdomen and presented brown urine. Blood test revealed abnormal liver function and elevated IgG4 (4.830g/L↑). 18F-FDG PET showed enlarged uncinate process and dilated bile duct tree. Mild increase of FDG uptake in uncinate process and head of pancreas indicated possible pancreatic malignancy, but the clinical evidence was not sufficient and histology examination was negative. 68Ga-FAPI PET revealed prominent increased radioactivity distribution in the entire pancreas and bile duct, suggesting IgG4-RD.

CONCLUSION

FAPI-04 is not only a good PET imaging tracer for tumors, but also for prominent fibroblast-mediated inflammation. FAPI imaging should be considered when the diagnosis using 18F-FDG imaging is ambiguous. The presented case illustrates that 68Ga-FAPI-04 PET is helpful in improving the differential diagnosis of pancreatitis and pancreatic cancer.

Для цитирования: Shou Yi, Xue Qiaoyi, Yuan Jianmin, Zhao Jun. 68Ga-FAPI-04 PET/MR is helpful in differential diagnosis of pancreatitis from pancreatic malignancy compared to 18F-FDG PET/CT: a case report.. European journal of hybrid imaging. 2021. DOI: 10.1186/s41824-021-00106-1.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.