MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7554/elife.79245

Медицинская библиотека · eLife · 2022

Analysis of allelic cross-reactivity of monoclonal IgG antibodies by a multiplexed reverse FluoroSpot assay.

Hoffmann-Veltung Henriette, Anabire Nsoh Godwin, Ofori Michael Fokuo, Janhmatz Peter, Ahlborg Niklas, Hviid Lars, Quintana Maria Del Pilar

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The issue of antibody cross-reactivity is of central importance in immunology, and not least in protective immunity to Plasmodium falciparum malaria, where key antigens show substantial allelic variation (polymorphism). However, serological analysis often does not allow the distinction between true cross-reactivity (one antibody recognizing multiple antigen variants) and apparent cross-reactivity (presence of multiple variant-specific antibodies), as it requires analysis at the single B-cell/monoclonal antibody level. ELISpot is an assay that enables that, and a recently developed multiplexed variant of ELISpot (FluoroSpot) facilitates simultaneous assessment of B-cell/antibody reactivity to several different antigens. In this study, we present a further enhancement of this assay that makes direct analysis of monoclonal antibody-level cross-reactivity with allelic variants feasible. Using VAR2CSA-type PfEMP1-a notoriously polymorphic antigen involved in the pathogenesis of placental malaria-as a model, we demonstrate the robustness of the assay and its applicability to analysis of true cross-reactivity of monoclonal VAR2CSA-specific antibodies in naturally exposed individuals. The assay is adaptable to the analysis of other polymorphic antigens, rendering it a powerful tool in studies of immunity to malaria and many other diseases.

Для цитирования: Hoffmann-Veltung Henriette, Anabire Nsoh Godwin, Ofori Michael Fokuo, Janhmatz Peter, Ahlborg Niklas, Hviid Lars, Quintana Maria Del Pilar. Analysis of allelic cross-reactivity of monoclonal IgG antibodies by a multiplexed reverse FluoroSpot assay.. eLife. 2022. DOI: 10.7554/elife.79245.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.