MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcct.2019.11.014

Медицинская библиотека · Journal of cardiovascular computed tomography · 2019

Influence of operator expertise and coronary luminal segmentation technique on diagnostic performance, precision and reproducibility of reduced-order CT-derived fractional flow reserve technique.

Ihdayhid Abdul Rahman, Sakaguchi Takuya, Kerrisk Bridget, Hislop-Jambrich Jacqui, Fujisawa Yasuko, Nerlekar Nitesh, Cameron James D, Seneviratne Sujith K, Ko Brian S

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Onsite workstation-based CT-derived Fractional-Flow-Reserve (CT-FFR) is accurate in assessing hemodynamic-significance of coronary stenoses. We aim to describe the influence of operator expertise and luminal-segmentation technique on the diagnostic performance, precision and reproducibility of CT-FFR in identifying hemodynamically-significant stenosis (FFR≤0.8).

METHODS

Forty-eight consecutive stable-patients (86 vessels) with suspected CAD underwent research indicated invasive-FFR and 320-detector CT-coronary-angiography (CTA). CT-FFR was derived using reduced-order model on standard desktop-computer. Semi-automated coronary luminal segmentation was performed using focused-technique with manual adjustments at regions of stenosis and calcification or comprehensive-technique with manual adjustments along the entire course of the vessel. CT-FFR analysis was performed using 3 blinded operators; core-laboratory engineer using focused-technique and radiographer and cardiologist using the comprehensive-technique. Diagnostic performance was assessed by area under receiver-operating-curve (AUC). Precision with invasive FFR was determined by Bland-Altman analysis, and reproducibility by intraclass-correlation-coefficient (ICC).

RESULTS

Diagnostic performance was comparable among operators (Engineer: AUC = 0.88, Radiographer 0.84; Cardiologist 0.87; P = 0.59). Coronary luminal-segmentation time was shortest using focused technique (engineer 6:17 ± 2.43 min), compared with comprehensive technique (cardiologist 14.83 ± 7.09, radiographer 24.74 ± 12.65; P < 0.001). Use of focused technique was associated with widest limits of agreement (LOA) with FFR and moderate intra-operator reproducibility (engineer LOA -0.20-0.33; ICC 0.66), when compared with the comprehensive technique which demonstrated narrower LOA and excellent reproducibility [radiographer (LOA -0.17-0.20, ICC = 0.91) and cardiologist (LOA-0.15-0.23, ICC = -0.93)]

CONCLUSION

A workstation-based CT-FFR technique was reproducible with high and comparable diagnostic performance among operators with different expertise. A comprehensive luminal segmentation technique was the most time-consuming and associated with the highest reproducibility and precision with FFR.

Для цитирования: Ihdayhid Abdul Rahman, Sakaguchi Takuya, Kerrisk Bridget, Hislop-Jambrich Jacqui, Fujisawa Yasuko, Nerlekar Nitesh, Cameron James D, Seneviratne Sujith K, Ko Brian S. Influence of operator expertise and coronary luminal segmentation technique on diagnostic performance, precision and reproducibility of reduced-order CT-derived fractional flow reserve technique.. Journal of cardiovascular computed tomography. 2019. DOI: 10.1016/j.jcct.2019.11.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.