BACKGROUND

The impact of a horizontal aorta (HA) on adverse events (AE) following in transcatheter aortic valve replacement (TAVR) is dealt controversially. Using new-generation self-expandable devices, we aimed to reevaluate an appropriate threshold of the aortic root angulation (ARA) in terms of HA and its impact on outcome.

METHODS

The 466 consecutive patients, who underwent transfemoral TAVR with self-expandable new-generation devices, were analyzed. Patients were classified into cases with HA (ARA ≥ 51°; n = 225; 48%) and without HA (ARA <51°; n = 241; 52%). Primary endpoints were device success and 30-day mortality. Secondary endpoints were specific AE according to VARC-2 definitions.

RESULTS

Contrast use (107.6 ± 50.1 vs. 94.1 ± 46.1 ml; p = .033) and radiation dose (3,176 [1,928-5,596] vs. 2,651 [1,643-4,394] Gyxcm2 ; p = .016) were higher in HA. Primary device success was comparable (97.1 vs. 97.8%; p = .773). A 30-day mortality (3.3 vs. 0.4%; p = .038, plogrank = 0.025), stroke (7.1 vs. 2.7%; p = .033), and major vascular complications (MVASC) (6.6 vs. 2.7%; p = .050) were more frequent in HA. Pronounced calcification of the noncoronary cusp and left ventricular outflow tract, the condition of HA, as well as repositioning maneuvers were independent predictors for overall specific AE.

CONCLUSION

An HA above 51° is associated with an increased rate of stroke, MVASC, and 30-day mortality. Valve size and asymmetric calcification affect the incidence of repositioning maneuvers and subsequent VARC-2 AE, indicating that an HA-together with specific anatomic features-remains a crucial factor for TAVR-related outcome with self-expandable new-generation devices.

Для цитирования: Veulemans Verena, Maier Oliver, Bosbach Georg, Polzin Amin, Piayda Kerstin, Afzal Shazia, Jung Christian, Westenfeld Ralf, Kelm Malte, Zeus Tobias. Novel insights on outcome in horizontal aorta with self-expandable new-generation transcatheter aortic valve replacement devices.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2020. DOI: 10.1002/ccd.28961.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.