MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11748-019-01284-3

Медицинская библиотека · General thoracic and cardiovascular surgery · 2020

Hemodynamic performance and incidence of patient-prosthesis mismatch of small-sized Trifecta pericardial aortic valves.

Manabe Susumu, Koinoshita Ryoji, Hirayama Daiki, Yuge Norihisa, Hirooka Kazunobu

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Small-sized bioprosthetic valves are sometimes associated with suboptimal hemodynamic performance, leading to a patient-prosthesis mismatch. Trifecta pericardial valves are designed to improve hemodynamic performance. The purpose of this study was to investigate the hemodynamic properties of small-sized Trifecta valves and their efficacy in preventing a patient-prosthesis mismatch.

METHODS

This was a retrospective analysis of 108 patients undergoing surgical aortic valve replacement with a Trifecta valve of 23 mm or less in a single Japanese institution. The hemodynamic performance was evaluated with an echocardiography examination in all patients after surgery, and the development of a patient-prosthesis mismatch was judged with the measured in vivo indexed effective orifice area.

RESULTS

There was one early and seven late mortalities. There were no valve explants due to structural valve deterioration. Postoperative mean pressure gradients of 19-, 21-, and 23-mm valves were 15.1, 11.4, and 9.0 mmHg, respectively. The effective orifice area of 19-, 21-, and 23-mm valves was 1.41, 1.69, and 1.78 cm2, respectively. Patient-prosthesis mismatch occurred in 14 patients (1 severe and 13 moderate) and the incidence was 13.0% (15.4% in 19 mm, 18.0% in 21 mm, and 3.3% in 23 mm).

CONCLUSIONS

The small-sized Trifecta valves showed excellent hemodynamic performance and were associated with a low incidence rate of patient-prosthesis mismatch.

Для цитирования: Manabe Susumu, Koinoshita Ryoji, Hirayama Daiki, Yuge Norihisa, Hirooka Kazunobu. Hemodynamic performance and incidence of patient-prosthesis mismatch of small-sized Trifecta pericardial aortic valves.. General thoracic and cardiovascular surgery. 2020. DOI: 10.1007/s11748-019-01284-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.