Implantation of one versus two MitraClips in the German TRAMI registry: Is more always better?

Puls Miriam, Huenlich Mark, Boekstegers Peter, Lubos Edith, von Bardeleben Ralph S, May Andreas E, Nickenig Georg, Baldus Stefan, Sievert Horst, Ouarrak Taoufik, Senges Jochen, Schillinger Wolfgang

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare baseline characteristics and outcomes in patients treated with either 1 or 2 MitraClips in the German TRAMI (Transcatheter Mitral Valve Interventions) registry.

BACKGROUND

The MitraClip community seems to silently assume that results should intrinsically be better after implantation of more than one clip, although data is still sparse.

METHODS

In 2010-2013, 803 patients were enrolled prospectively into TRAMI (461 one-clip and 312 two-clip procedures). Follow-up was performed centrally at 30 days and 1 year.

RESULTS

Baseline characteristics of TRAMI-patients with two clips differed significantly from single-clip patients regarding constitutional (more men, taller body height) and heart failure-related factors (larger left ventricular dimensions, reduced left ventricular ejection fraction, more severe heart failure). Also, a significant increase in two-clip procedures over time was present. After propensity score matching for differing baseline characteristics, residual moderate mitral regurgitation (MR) occurred more frequently after implantation of two clips, whereas residual severe MR could more frequently be observed after one-clip procedures. However, no or mild residual MR at discharge was present in 71.6% after single-clip and in 70.1% after two-clips implantation (p = .81). After 1 year, no significant differences regarding mortality or New York Heart Association status could be detected in the propensity matched cohorts. However, TRAMI-patients treated with two clips had a significantly higher incidence of cerebral-vascular events (p = .02).

CONCLUSIONS

TRAMI data cannot support the theory that implantation of more than one clip is associated with better clinical outcomes. The finding of more cerebral-vascular events after two-clip procedures might be hypothesis-generating.

Для цитирования: Puls Miriam, Huenlich Mark, Boekstegers Peter, Lubos Edith, von Bardeleben Ralph S, May Andreas E, Nickenig Georg, Baldus Stefan, Sievert Horst, Ouarrak Taoufik, Senges Jochen, Schillinger Wolfgang. Implantation of one versus two MitraClips in the German TRAMI registry: Is more always better?. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2019. DOI: 10.1002/ccd.28613.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.