MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/23258160-20220412-01

Медицинская библиотека · Ophthalmic surgery, lasers & imaging retina · 2022

Refill-Exchange Procedure of the Port Delivery System With Ranibizumab: Overview and Clinical Trial Experience.

Khanani Arshad M, Graff Jordan M, Marcus Dennis M, Wykoff Charles C, Jhaveri Chirag D, Barteselli Giulio, Malhotra Varun K, Menezes Alicia R, Callaway Natalia F

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To describe the Port Delivery System with ranibizumab refill-exchange procedure.

METHODS

Procedure based on the clinical trial program in patients with retinal diseases.

RESULTS

The refill-exchange procedure is performed under topical anesthesia and strict aseptic conditions. Supplemental task lighting and magnification are recommended throughout the procedure. Ranibizumab is aseptically transferred from the vial with the filter needle and air is removed from the syringe. The filter needle is then replaced with the refill needle; any remaining air is removed from the syringe and the plunger is advanced to the 0.1-mL mark. Targeting the implant septum center, the refill needle is inserted perpendicularly to the globe until the soft stop contacts the conjunctiva (perpendicular orientation and conjunctival contact are maintained throughout the procedure); a cotton-tipped applicator is recommended for globe stabilization. The entire syringe contents are slowly injected over 5-10 seconds while existing solution fills the fluid collection reservoir. Once completed, the needle is carefully withdrawn while maintaining perpendicularity. The procedure can be successfully performed in rare, specific cases, including subconjunctival thickening or fibrous capsule formation, fluid-filled bleb formation, and corneal patch grafts.

CONCLUSION

The procedure is straightforward but distinct from intravitreal injections and requires adherence to standardized techniques. With appropriate preparation, the procedure can be performed in specific cases. [Ophthalmic Surg Lasers Imaging Retina. 2022;53:257-265.].

Для цитирования: Khanani Arshad M, Graff Jordan M, Marcus Dennis M, Wykoff Charles C, Jhaveri Chirag D, Barteselli Giulio, Malhotra Varun K, Menezes Alicia R, Callaway Natalia F. Refill-Exchange Procedure of the Port Delivery System With Ranibizumab: Overview and Clinical Trial Experience.. Ophthalmic surgery, lasers & imaging retina. 2022. DOI: 10.3928/23258160-20220412-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.