MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/tvst.11.4.9

Медицинская библиотека · Translational vision science & technology · 2022

Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva.

Nakamura Kenichi, Fujimoto Tomokazu, Okada Miho, Maki Kentaro, Shimazaki Atsushi, Kato Masatomo, Inoue Toshihiro

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate tissue reactivity to, and the stability of, glaucoma drainage device materials placed under rabbit conjunctiva in vivo.

METHODS

Disks (diameter, 3 mm; thickness, ∼0.3 mm) fabricated from poly(styrene-block-isobutylene-block-styrene) (SIBS), silicone, stainless-steel, or glutaraldehyde cross-linked collagen (GACLC) were inserted under rabbit conjunctiva. Conjunctival and scleral sections obtained at 4, 8, and 12 weeks after surgery were immunostained for α-smooth muscle actin (SMA). The ratio of the maximum thickness of the α-SMA-positive conjunctiva to the scleral thickness (α-SMA/S ratio) was calculated. The in vivo stability of the drainage devices at 12 weeks after insertion was evaluated.

RESULTS

The mean α-SMA/S ratios of the SIBS and silicone groups were lower than that of the stainless-steel group at 4 weeks after surgery (P < 0.05), and that of the SIBS group was lower than that of the GACLC group (P < 0.05). The ratios at 8 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P < 0.01). The ratios at 12 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P < 0.05). The surface areas of GACLC disks explanted from conjunctivae were significantly lower than that of intact disks (P < 0.01).

CONCLUSIONS

SIBS and silicon were highly biostable and exhibited less tissue reactivity than GACLC in vivo.

TRANSLATIONAL RELEVANCE: Comparisons of materials using animal models can predict the clinical stability and safety of such materials in humans.

Для цитирования: Nakamura Kenichi, Fujimoto Tomokazu, Okada Miho, Maki Kentaro, Shimazaki Atsushi, Kato Masatomo, Inoue Toshihiro. Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva.. Translational vision science & technology. 2022. DOI: 10.1167/tvst.11.4.9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.