A simple plaster for screening for diabetic neuropathy: a diagnostic test accuracy systematic review and meta-analysis.
Аннотация
OBJECTIVE
Neuropad is an adhesive indicator test applied at the plantar surface of the foot that detects sweating through color change. We examined the diagnostic accuracy of this simple plaster as triage test for screening for clinically relevant diabetic sensorimotor polyneuropathy in adult outpatients with type 1 or type 2 diabetes.
MATERIALS/
METHODS
Systematic review and meta-analysis of diagnostic accuracy studies. We searched Medline, Embase, Cochrane Library, Biosis Previews, Web of Science, Scopus and gray literature without date or language restrictions. We pooled estimates of sensitivity and specificity, and fitted hierarchical models to produce summary receiver operating characteristic curves. We assessed methodological quality of included studies utilizing the Quality Assessment of Diagnostic Accuracy Studies 2 tool.
RESULTS
Eighteen studies with 3470 participants met the inclusion criteria. Average sensitivity and specificity were 86% (95% CI 79 to 91) and 65% (95% CI 51 to 76) respectively. Likelihood ratios (LRs) were LR+=2.44 and LR-=0.22. Subgroup analyses per reference standard utilized provided similar estimates. Most studies were at risk of bias for patient selection and use of index or reference test, and had concerns regarding applicability due to patient selection.
CONCLUSION
The adhesive indicator test has reasonable sensitivity and could be used for triage of diabetic neuropathy to rule out foot at risk. Patients who tested positive should be referred to specialized care to establish a definite diagnosis. There is insufficient evidence for effectiveness on patient-important outcomes and cost-effectiveness of implementation in the diagnostic pathway compared with the standard clinical examination.