Characteristics in the beat-to-beat laser-Doppler waveform indices in subjects with diabetes.

Hsiu Hsin, Hu Hsiao-Feng, Wu Guan-Shian, Hsiao Fone-Ching

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

MOTIVATIONS: The present study performed laser-Doppler flowmetry (LDF) measurements on the skin surface around the ankle with the aim of verifying if beat-to-beat analysis of the LDF waveform can help to discriminate the microcirculatory-blood-flow (MBF) characteristics between diabetic, prediabetic, and healthy subjects.

METHODS

84 subjects were assigned to three groups (diabetic, prediabetic, and normal) according to the results of oral glucose tolerance tests. Beat-to-beat analysis was performed on the pulsatile LDF waveform to obtain foot delay time (FDT), flow rise time (FRT), and the corresponding MBF-variability parameters (FDTCV and FRTCV).

RESULTS

Relative to the control group, FDT and FRT were significantly shorter in prediabetic subjects, FDT was significantly shorter in diabetic subjects, and FRTCV and FDTCV were significantly larger in prediabetic and diabetic subjects. There were no significant associations for FRT after adjustment for age and gender.

CONCLUSION

The present results indicate that FRT may help to discriminate differences in the elastic properties of local vascular beds during diabetes or even during prediabetic stages. The proposed blood-filling-volume model can help to explain the underlying mechanism. The present findings may aid the noninvasive early detection of diabetes-associated vascular damage, and could be used in the development of home-care and telemedicine applications.

Для цитирования: Hsiu Hsin, Hu Hsiao-Feng, Wu Guan-Shian, Hsiao Fone-Ching. Characteristics in the beat-to-beat laser-Doppler waveform indices in subjects with diabetes.. Clinical hemorheology and microcirculation. 2014. DOI: 10.3233/ch-131794.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.