MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-13096-y

Медицинская библиотека · Scientific reports · 2025

Digital measurement of pupil size, corneal size, and eccentricity in Guinea pigs using python compared with traditional OCT.

Wu Hao, Qiao Zhongbao, Cheng Chi, Luo Wenting, Wan Ting, Lu Na, Qiao Tong, Di Yue

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

UNLABELLED: To develop a Python-based digital technique for accurate measurement of pupil size, corneal size, and eccentricity in guinea pigs, and to validate its efficiency and accuracy against traditional OCT methods in ophthalmology research.

METHODS

Fourteen healthy guinea pigs were selected, and the eye images were captured using a camera, and the image analysis program was written by Python 3.9. The program integrated edge detection (Canny algorithm), curve fitting (conic curve equation) and pixel-actual distance conversion modules, and designed a graphical user interface (GUI) to visualize the operation. Measured parameters included pupil size, corneal size and eccentricity to compare the difference between in vivo and ex vivo measurements and to verify the accuracy of the method.

RESULTS

The Python program clearly identified the guinea pig pupil and corneal limbus, and the fitted curves were in high agreement with the actual contours. Pupil and corneal size measured with an accuracy of 0.01 mm. In vivo and in vitro measurements showed that pupil size increased significantly after ex vivo (p < 0.001), whereas there was no significant difference in eccentricity (p = 0.38). Compared to optical coherence tomography (OCT), the method did not differ significantly in accuracy (p > 0.05), but significantly improved efficiency and reduced reliance on specialized equipment.

CONCLUSION

The Python-based digital measurement technique can effectively and accurately quantify the morphological parameters of the guinea pig eye, providing reliable technical support for non-contact measurements in experimental animals.

Для цитирования: Wu Hao, Qiao Zhongbao, Cheng Chi, Luo Wenting, Wan Ting, Lu Na, Qiao Tong, Di Yue. Digital measurement of pupil size, corneal size, and eccentricity in Guinea pigs using python compared with traditional OCT.. Scientific reports. 2025. DOI: 10.1038/s41598-025-13096-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.