MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s40744-022-00432-1

Медицинская библиотека · Rheumatology and therapy · 2022

A Randomised Controlled Trial Comparing the Pharmacokinetics and Tolerability of the Proposed Adalimumab Biosimilar MSB11022 Delivered via Autoinjector and Pre-filled Syringe in Healthy Subjects.

Sabet Ahad, Dickerson Daniel S, Kunina Eugenia E, Buccarello Anna Lucia, Monnet Joëlle

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The aim of the study was to demonstrate the bioequivalence, and compare the safety and tolerability of MSB11022, a proposed biosimilar of adalimumab, when delivered by either an autoinjector (AI) or a pre-filled syringe (PFS).

METHODS

In this pharmacokinetic (PK), parallel group, open-label study, 216 healthy volunteers were randomised 1:1 to receive a single subcutaneous injection of a 40 mg/0.8 mL dose of MSB11022 administered via AI or PFS. Coprimary PK endpoints were maximum observed concentration (Cmax), area under the concentration-time curve (AUC) from time 0 to the last quantifiable concentration (AUC0-t), and AUC from time 0 extrapolated to infinity (AUC0-inf). PK equivalence between the AI and PFS administration methods was declared if the 90% confidence intervals (CIs) for the ratio of geometric least square means was entirely contained within the 80-125% equivalence margin for all coprimary endpoints. Safety and tolerability were also evaluated.

RESULTS

The 90% CI for the three coprimary PK endpoints (Cmax, AUC0-t and AUC0-inf) were entirely contained within the predefined equivalence margins of 80-125%. Mean serum concentration-time profiles were similar following injection via AI or PFS. Treatment-emergent adverse events (TEAEs) were comparable across both treatment groups. Study device-related TEAEs were reported by 11.3% and 13.1% of subjects in the AI and PFS treatment groups, respectively. Study drug-related TEAEs were reported by 28.3% and 34.6% of subjects in the AI and PFS treatment groups, respectively. Few subjects experienced injection-site reactions, mainly pain and erythema, regardless of the administration method.

CONCLUSION

Delivery of MSB11022 via an AI is bioequivalent to delivery via a PFS. The safety and tolerability profile of MSB11022 was comparable across administration methods. The development of an AI for MSB11022 provides a choice of self-injection devices available to patients, potentially improving treatment compliance.

TRIAL REGISTRATION: ClinicalTrials.gov trial identifier: NCT04018599.

Для цитирования: Sabet Ahad, Dickerson Daniel S, Kunina Eugenia E, Buccarello Anna Lucia, Monnet Joëlle. A Randomised Controlled Trial Comparing the Pharmacokinetics and Tolerability of the Proposed Adalimumab Biosimilar MSB11022 Delivered via Autoinjector and Pre-filled Syringe in Healthy Subjects.. Rheumatology and therapy. 2022. DOI: 10.1007/s40744-022-00432-1.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.