Perfluorocarbon-Assisted Emulsified Silicone Oil Removal: A Simple and Effective Technique.

Abdullah Omer Othman

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe and evaluate a perfluorocarbon liquid (PFCL)-assisted technique for removal of emulsified silicone oil following vitreoretinal surgery.

METHODS

This retrospective interventional case series conducted at a single vitreoretinal center included 20 eyes with significant emulsified silicone oil following long-term tamponade. PFCL was used intraoperatively to mobilize and evacuate residual silicone oil droplets. Clinical outcomes included residual emulsified oil, intraocular pressure, and best-corrected visual acuity over a mean follow-up of 24.2 months.

RESULTS

At final follow-up, 17 eyes (85%) showed complete clearance of visible emulsified silicone oil. Sparse microscopic droplets persisted in 3 eyes (15%) without clinical significance. No eye developed elevated intraocular pressure (>21 mmHg) or corneal complications. Best-corrected visual acuity improved or remained stable in all eyes, with 65% achieving an improvement of ≥2 Snellen lines.

CONCLUSION

PFCL-assisted washout may represent a practical adjunctive technique for managing emulsified silicone oil in challenging cases, achieving high rates of clinical clearance with a favorable safety profile. Larger prospective studies are required to validate these findings.

Для цитирования: Abdullah Omer Othman. Perfluorocarbon-Assisted Emulsified Silicone Oil Removal: A Simple and Effective Technique.. Clinical ophthalmology (Auckland, N.Z.). 2026. DOI: 10.2147/opth.s595220.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.