MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11739-023-03414-5

Медицинская библиотека · Internal and emergency medicine · 2023

The measurement of the left ventricle ejection fraction by a bedside FoCUS examination.

Martocchia Antonio, Piccoli Cinzia, Notarangelo Michele Fortunato, Sergi Daniela, Ostrowska Beata, Martelletti Paolo, Savoia Carmine, De Biase Luciano, Sesti Giorgio

СтатьяПеревод пока не подготовлен

Аннотация

The use of point-of-care ultrasound is rapidly increasing in medical practice. This study aims to evaluate the left ventricle systolic function by the bedside focus cardiac ultrasound (FoCUS). We consecutively enrolled n.59 patients of the Emergency Medicine Unit of S. Andrea Hospital. Every patient received a bedside FoCUS examination to estimate the left ventricle (LV) ejection fraction (EF); the LV EF measurements were compared with those obtained by standard echocardiography (as gold standard). The LV EF obtained by the bedside FoCUS examination and the standard echocardiography, resulted, respectively: 50.2 ± 15.1% (by the Quinones equation), 39.5 + 12.0% (by the Lvivo app) and 53.7 + 11.1% (by the standard echocardiography). The correlations between the bedside FoCUS EF measurements versus standard echocardiography were statistically significant: r =  + 0.694 p < 1.9 × 10-6 (Quinones equation, Bland-Altman analysis mean = - 2.3%) and r =  + 0.571 p < 0.01 (Lvivo app, Bland-Altman analysis mean = - 13.3%). In conclusion, the present study showed a high accuracy of the bedside FoCUS EF evaluations, which may support the diagnosis of the heart failure in an emergency setting without delaying. The EF measurements by the operational method are more precise than those obtained by the unselected images of the software application.

Для цитирования: Martocchia Antonio, Piccoli Cinzia, Notarangelo Michele Fortunato, Sergi Daniela, Ostrowska Beata, Martelletti Paolo, Savoia Carmine, De Biase Luciano, Sesti Giorgio. The measurement of the left ventricle ejection fraction by a bedside FoCUS examination.. Internal and emergency medicine. 2023. DOI: 10.1007/s11739-023-03414-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.