MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mej.0000000000000801

Медицинская библиотека · European journal of emergency medicine : official journal of the European Society for Emergency Medicine · 2021

Goal-directed ultrasound protocol in patients with nontraumatic undifferentiated shock in the emergency department: prospective dual centre study.

Leroux Pierre, Javaudin François, Le Bastard Quentin, Lebret Yannick, Pes Philippe, Arnaudet Idriss, Vignaud Frédéric, Montassier Emmanuel, Le Conte Philippe

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

IMPORTANCE

Early identification of the cause of shock is associated with better prognosis.

OBJECTIVE

The aim of this study was to explore the performances of an ultrasound protocol (echoSHOCK) to diagnose the cause of shock in the emergency department (ED).

DESIGN, SETTINGS AND

PARTICIPANTS

This was a prospective study performed in two EDs. Included patients were older than 18 years admitted with shock. After routine workup strategy, the suspected cause of shock and the planned treatment were reported. The echoSHOCK protocol, using only B mode, was then performed. After performing echoSHOCK, the investigator reported the same two items.

INTERVENTION: echoSHOCK protocol that assessed: compressive pericardial effusion (tamponade), right ventricle dilatation and flattening of the septum, left ventricle dimension and systolic function, indices of hypovolemia.

OUTCOMES MEASURE AND ANALYSIS: We defined four different causes for shock (tamponade, acute cor pulmonale, cardiogenic and hypovolemia). The primary endpoint was the degree of agreement of the routine workup and echoSHOCK with an expert panel.

MAIN

RESULTS

85 patients [mean age of 73 (14) years] were included. Kappa coefficients between routine strategy and echoSHOCK for the cause of shock, with the expert panel were 0.33 (95% CI, 0.26-0.4) and 0.88 (95% CI, 0.83-0.93), respectively. Likewise, for the planned treatment, kappa were 0.21 (95% CI, 0.14-0.28) and 0.9 (95% CI, 0.85-0.94), respectively. The physician's confidence increased from 3.9 (2.1) before echoSHOCK to 9.3 (1.1) after, (P < 0.001).

CONCLUSION

This study suggested that echoSHOCK significantly increased the ability to determine the cause of undifferentiated shock in the ED.

Для цитирования: Leroux Pierre, Javaudin François, Le Bastard Quentin, Lebret Yannick, Pes Philippe, Arnaudet Idriss, Vignaud Frédéric, Montassier Emmanuel, Le Conte Philippe. Goal-directed ultrasound protocol in patients with nontraumatic undifferentiated shock in the emergency department: prospective dual centre study.. European journal of emergency medicine : official journal of the European Society for Emergency Medicine. 2021. DOI: 10.1097/mej.0000000000000801.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.