MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0300060521997588

Медицинская библиотека · The Journal of international medical research · 2021

Differences between diabetic and non-diabetic nephropathy patients in cardiac structure and function at the beginning of hemodialysis and their impact on the prediction of mortality.

Tang Chao, Ouyang Han, Huang Jian, Zhu Jing, Gu Xiaosong

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To characterize differences in cardiac structure and function in hemodialysis (HD) patients with diabetic nephropathy (DN) and in those without using echocardiography and to determine their impact on the prediction of mortality using echocardiographic parameters.

METHODS

Clinical, laboratory, and echocardiographic data were collected from patients commencing HD.

RESULTS

Compared with those without DN, patients with DN had lower peak velocity of the early diastolic wave (e'), larger left atria, and higher peak early diastolic velocity (E)/e' and peak velocity of tricuspid regurgitation (TR). In addition, a larger proportion of DN patients had a combination of left ventricular (LV) diastolic dysfunction, cardiac valve calcification, moderate-to-severe cardiac valve regurgitation (CVR), and at least moderate pericardial effusion (PE). After accounting for age, sex, smoking, hypertension, hemoglobin, and albumin, DN was responsible for e'  < 10 cm/s, E/e' >13 m/s, TR >2.8 m/s, LV diastolic dysfunction, CVR, and PE. LV diastolic dysfunction and E/e' >13 were the most useful predictors of mortality in patients with DN.

CONCLUSIONS

Patients with DN who undergo HD tend to have worse LV diastolic function and are more likely to have heart valve problems. LV diastolic dysfunction and E/e' are predictors of death in DN patients.

Для цитирования: Tang Chao, Ouyang Han, Huang Jian, Zhu Jing, Gu Xiaosong. Differences between diabetic and non-diabetic nephropathy patients in cardiac structure and function at the beginning of hemodialysis and their impact on the prediction of mortality.. The Journal of international medical research. 2021. DOI: 10.1177/0300060521997588.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.