MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-021-00943-x

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2021

Ablation of mitral annular flutter ablation utilizing a left atrial anterior line versus a lateral mitral isthmus line: a systematic review and meta-analysis.

Aldaas Omar M, Lupercio Florentino, Lin Andrew Y, Han Frederick T, Hoffmayer Kurt S, Raissi Farshad, Ho Gordon, Krummen David, Feld Gregory K, Hsu Jonathan C

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

PURPOSE: Mitral annular flutter (MAF) is a common arrhythmia after atrial fibrillation ablation. We sought to compare the efficacy and safety of catheter ablation utilizing either a left atrial anterior wall (LAAW) line or a lateral mitral isthmus (LMI) line.

METHODS

We performed a systematic review for all studies that compared LAAW versus LMI lines. Risk ratio (RR) and mean difference (MD) 95% confidence intervals were measured for dichotomous and continuous variables, respectively.

RESULTS

Four studies with a total of 594 patients were included, one of which was a randomized control trial. In the LMI ablation group, 40% of patients required CS ablation. There were no significant differences in bidirectional block (RR 1.26; 95% CI, 0.94-1.69) or ablation time (MD -1.5; 95% CI, -6.11-3.11), but LAAW ablation was associated with longer ablation line length (MD 11.42; 95% CI, 10.69-12.14) and longer LAA activation delay (MD 67.68; 95% CI, 33.47-101.89.14) when compared to LMI. There was no significant difference in pericardial effusions (RR 0.36; 95% CI, 0.39-20.75) between groups and more patients were maintained sinus rhythm (RR 1.19; 95% CI, 1.03-1.37, p = 0.02) who underwent LAAW compared to LMI.

CONCLUSION

Ablation of mitral annular flutter with a LAAW line compared to a LMI line showed no difference in rates of acute bidirectional block, ablation time, or pericardial effusion. However, LAAW ablation required a longer ablation line length, resulted in greater LAA activation delayed and was associated with more sinus rhythm maintenance, with the added advantage of avoiding ablation in the CS.

Для цитирования: Aldaas Omar M, Lupercio Florentino, Lin Andrew Y, Han Frederick T, Hoffmayer Kurt S, Raissi Farshad, Ho Gordon, Krummen David, Feld Gregory K, Hsu Jonathan C. Ablation of mitral annular flutter ablation utilizing a left atrial anterior line versus a lateral mitral isthmus line: a systematic review and meta-analysis.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2021. DOI: 10.1007/s10840-021-00943-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.