Comparison of postoperative ciliary body changes associated with the use of 23-gauge and 20-gauge system for pars plana vitrectomy.
Аннотация
BACKGROUND
To compare the ciliary body changes associated with the use of 23-gauge (23G) and 20-gauge (20G) systems for pars plana vitrectomy.
METHODS
A total of 60 patients (60 eyes) with idiopathic epiretinal membrane who were scheduled for surgical treatment were selected and randomly assigned to 20G group or 23G group. Time required for incision making, vitrectomy, and incision closure was compared between the two groups. Changes in ciliary body were evaluated by ultrasound microscopy (UBM). Anterior chamber inflammation was assessed with laser flare meter instrument.
RESULTS
Incision-making time (4.5 ± 0.9 min) and incision-closure time (2.8 ± 0.7 min) in the 23G group were significantly shorter than those in the 20G group (10.1 ± 1.5 min and 11.3 ± 2.2 min, respectively). No significant intergroup difference was observed with respect to time required for vitrectomy (21.6 ± 3.3 min and 20.7 ± 3.2 min, respectively). Ciliary body thickness in the 23G group recovered back to preoperative levels after 4 weeks, as against 8 weeks in the 20G group. Postoperative ciliary body thickness in the 20G group was significantly higher than that in the 23G group (p < 0.05). The aqueous protein concentration in 23G group recovered back to preoperative levels after 2 weeks, as against 4 weeks in the 20G group. Postoperative aqueous protein concentration in the 20G group was significantly higher than that in the 23G group (p < 0.05).
CONCLUSIONS
The use of 23G system was associated with significantly milder injury to the ciliary body as compared to that associated with the use of 20G system.
TRIAL REGISTRATION: The study was retrospectively registered on Chinese Clinical Trial Registry. The clinical study registration number was ChiCTR-INR-17011082 . Date of registration: 2017-04-07.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.