MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2026.467140

Медицинская библиотека · Journal of chromatography. A · 2026

On-site multi-matrix profiling of per- and polyfluoroalkyl substances using mobile liquid chromatography - mass spectrometry.

Mikhail Ibraam E, Mai Yonglin, Lebanov Leo, Lam Shing Chung, Durage Kaushalya Kankani, Firme Boyjie, Askeland Matthew, Gooley Andrew, Paull Brett

СтатьяПеревод пока не подготовлен

Аннотация

This study demonstrates rapid, on-site detection of per- and polyfluoroalkyl substances (PFAS) at a legacy-impacted site along Barilla Rivulet in Cambridge, Tasmania, using a mobile liquid chromatography-mass spectrometry (LC-MS) laboratory (lab-in-a-van). Ten key PFAS were monitored in freshwater, soil, and soil pore-water samples, providing an integrated view of their distribution and mobility. Sample collection, on-site preparation, and LC-MS analysis of standards and 13 environmental samples were finished within six hours. The compact LC-MS system, pallet-framed in a van, combines a Versiti liquid chromatograph with a Shimadzu autosampler and single quadrupole mass spectrometer. The system was transported from Victoria to Tasmania, where on-site analysis was conducted using an LC-MS method with a total run time of <8 min and limits of detection (LODs) ranging from 0.06 to 0.84 µg/L. Inter-day precision showed %RSD ≤18.3%, and on-site analysis of a certified proficiency test soil sample yielded deviations of 4-35% relative to reference values. Freshwater samples from Barilla Rivulet and soil pore-water samples collected via a ceramic pore-water sampler were processed using a rapid solid-phase extraction (SPE) protocol, completed in 30 min per batch of 3-5 samples, while soil samples were extracted using a solid-liquid extraction (SLE) protocol. The combined concentration of the targeted PFAS ranged from 1.5-2.4 µg/L in freshwater samples, 5.9-22.9 µg/kg in soil, and 0.3-1.9 µg/L in soil pore-water. Clear distinctions were observed in the distribution of short- and long-chain homologues, as well as between carboxylic- and sulfonic-acid PFAS across soil and soil pore water. This study demonstrates that a rapid multi-matrix PFAS survey can be conducted on-site using mobile LC-MS, providing a practical solution for time-critical environmental assessments and supporting data-driven remediation decisions.

Для цитирования: Mikhail Ibraam E, Mai Yonglin, Lebanov Leo, Lam Shing Chung, Durage Kaushalya Kankani, Firme Boyjie, Askeland Matthew, Gooley Andrew, Paull Brett. On-site multi-matrix profiling of per- and polyfluoroalkyl substances using mobile liquid chromatography - mass spectrometry.. Journal of chromatography. A. 2026. DOI: 10.1016/j.chroma.2026.467140.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.