DOI 10.1162/imag.a.1262

Медицинская библиотека · Imaging neuroscience (Cambridge, Mass.) · 2026

Frame-wise multi-echo distortion correction for superior functional MRI.

Van Andrew N, Montez David F, Laumann Timothy O, Cho Philip N, Suljic Vahdeta, Madison Thomas, Baden Noah J, Ramirez-Perez Nadeshka, Scheidter Kristen M, Monk Julia S, Whiting Forrest I, Adeyemo Babatunde, Chauvin Roselyne J, Krimmel Samuel R, Metoki Athanasia, Rajesh Aishwarya, Roland Jarod L, Salo Taylor, Wang Anxu, Weldon Kimberly B, Sotiras Aristeidis, Shimony Joshua S, Kay Benjamin P, Nelson Steven M, Tervo-Clemmens Brenden, Marek Scott A, Vizioli Luca, Yacoub Essa, Satterthwaite Theodore D, Gordon Evan M, Fair Damien A, Tisdall M Dylan, Dosenbach Nico U F

СтатьяПеревод пока не подготовлен

Аннотация

Functional MRI (fMRI) data are severely distorted by magnetic field (B0) inhomogeneities, which currently must be corrected using separately acquired field map data. However, changes in the head position of a participant across fMRI frames cause changes in the B0 field, preventing accurate correction of geometric distortions. Movement during field map acquisitions corrupts field maps, preventing distortion correction altogether. In this study, we use multi-echo (ME) fMRI data to dynamically sample and correct for magnetic field image distortions caused by head motion. Our distortion correction pipeline, MEDIC (Multi-Echo DIstortion Correction), leverages magnetic field inhomogeneity information found in the difference between echoes and uses it to correct for distortion on a frame-by-frame basis. Here, we demonstrate that MEDIC's frame-wise distortion correction decreases the impact of head motion on resting-state functional connectivity (RSFC) maps and improves alignment to anatomy when compared with the prior gold standard approach (i.e., FSL TOPUP). Enhanced frame-wise distortion correction with MEDIC, without the requirement for field map collection, furthers the benefit of cutting-edge multi-echo fMRI imaging over single-echo fMRI.

Для цитирования: Van Andrew N, Montez David F, Laumann Timothy O, Cho Philip N, Suljic Vahdeta, Madison Thomas, Baden Noah J, Ramirez-Perez Nadeshka, Scheidter Kristen M, Monk Julia S, Whiting Forrest I, Adeyemo Babatunde, Chauvin Roselyne J, Krimmel Samuel R, Metoki Athanasia, Rajesh Aishwarya, Roland Jarod L, Salo Taylor, Wang Anxu, Weldon Kimberly B, Sotiras Aristeidis, Shimony Joshua S, Kay Benjamin P, Nelson Steven M, Tervo-Clemmens Brenden, Marek Scott A, Vizioli Luca, Yacoub Essa, Satterthwaite Theodore D, Gordon Evan M, Fair Damien A, Tisdall M Dylan, Dosenbach Nico U F. Frame-wise multi-echo distortion correction for superior functional MRI.. Imaging neuroscience (Cambridge, Mass.). 2026. DOI: 10.1162/imag.a.1262.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.