Multi-Laboratory Evaluation of Prototype Dried Blood Spot Quality Control Materials for Creatine Kinase-MM Newborn Screening Assays.

Dantonio Paul, Tavakoli Norma P, Migliore Brooke, McCown Elizabeth, Lim Timothy, Park Sunju, Caggana Michele, Kucera Katerina S, Phan Han, Street Natalie, Petritis Konstantinos, Vogt Robert F

СтатьяПеревод пока не подготовлен

Аннотация

Pilot studies to detect newborns with Duchenne Muscular Dystrophy (DMD) by newborn bloodspot screening (NBS) have been conducted under the New York State Newborn Screening Program (NYS) and are currently in progress as part of the Early Check Program at Research Triangle Institute (RTI) International. The Newborn Screening Quality Assurance Program (NSQAP) at the U.S. Centers for Disease Control and Prevention (CDC) produced a set of seven prototype dried blood spot (DBS) reference materials spiked with varying levels of creatine kinase MM isoform (CK-MM). These DBS were evaluated over a 3-week period by CDC, NYS, and RTI, all using the same CK-MM isoform-specific fluoroimmunoassay. Results from each laboratory were highly correlated with the relative proportion of CK-MM added to each of the six spiked pools. Based on reference ranges established by NYS and RTI for their pilot studies, these contrived DBS collectively spanned the CK-MM ranges found in typical newborns and the elevated ranges associated with DMD. This set allows quality assessment over the wide range of fluctuating CK-MM levels in typical and DMD-affected newborns.

Для цитирования: Dantonio Paul, Tavakoli Norma P, Migliore Brooke, McCown Elizabeth, Lim Timothy, Park Sunju, Caggana Michele, Kucera Katerina S, Phan Han, Street Natalie, Petritis Konstantinos, Vogt Robert F. Multi-Laboratory Evaluation of Prototype Dried Blood Spot Quality Control Materials for Creatine Kinase-MM Newborn Screening Assays.. International journal of neonatal screening. 2023. DOI: 10.3390/ijns9010013.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.