MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2018.06.005

Медицинская библиотека · International journal of cardiology · 2018

Response to cardiac resynchronization therapy is determined by intrinsic electrical substrate rather than by its modification.

Strik Marc, Ploux Sylvain, Huntjens Peter R, Nguyên Uyên Châu, Frontera Antionio, Eschalier Romain, Dubois Remi, Ritter Philippe, Klotz Nicholas, Vernooy Kevin, Haïssaguerre Michel, Crijns Harry J G M, Prinzen Frits W, Bordachar Pierre

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Electrocardiographic mapping (ECM) expresses electrical substrate through magnitude and direction of the activation delay vector (ADV). We investigated to what extent the response to cardiac resynchronization therapy (CRT) is determined by baseline ADV and by ADV modification through CRT and optimization of left ventricular (LV) pacing site.

METHODS

ECM was performed in 79 heart failure patients (4 RBBB, 12 QRS < 120 ms, 23 non-specific conduction delay [NICD] and 40 left bundle branch block [LBBB]). 67 patients (QRS ≥ 120 ms) underwent CRT implantation and in 26 patients multiple LV pacing site optimization was performed. ADV was calculated from locations/depolarization times of 2000 virtual epicardial electrodes derived from ECM. Acute response was defined as ≥10% LVdP/dtmax increase, chronic response by composite clinical score at 6 months.

RESULTS

During intrinsic conduction, ADV direction was similar in patients with QRS < 120 ms, NICD and LBBB, pointing towards the LV free wall, while ADV magnitude was larger in LBBB (117 ± 25 ms) than in NICD (70 ± 29 ms, P < 0.05) and QRS < 120 ms (52 ± 14 ms, P < 0.05). Intrinsic ADV accurately predicted the acute (AUC = 0.93) and chronic (AUC = 0.90) response to CRT. ADV change by CRT only moderately predicted response (highest AUC = 0.76). LV pacing site optimization had limited effects: +3 ± 4% LVdP/dtmax when compared to conventional basolateral LV pacing.

CONCLUSION

The baseline electrical substrate, adequately measured by ADV amplitude, strongly determines acute and chronic CRT response, while the extent of its modification by conventional CRT or by varying LV pacing sites has limited effects.

Для цитирования: Strik Marc, Ploux Sylvain, Huntjens Peter R, Nguyên Uyên Châu, Frontera Antionio, Eschalier Romain, Dubois Remi, Ritter Philippe, Klotz Nicholas, Vernooy Kevin, Haïssaguerre Michel, Crijns Harry J G M, Prinzen Frits W, Bordachar Pierre. Response to cardiac resynchronization therapy is determined by intrinsic electrical substrate rather than by its modification.. International journal of cardiology. 2018. DOI: 10.1016/j.ijcard.2018.06.005.