DOI 10.1016/j.jelectrocard.2018.02.009
Electrocardiographic changes and conduction disturbances after transfemoral aortic valve implantation with Edwards Sapien 3 prosthesis.
Аннотация
OBJECTIVES
The aim of this study is to describe electrocardiographic changes and conduction abnormalities in patients undergoing transcatheter aortic valve implantation (TAVI).
METHODS
76 patients who underwent TAVI using Edwards Sapien 3 prosthesis were included, comparing electrocardiographic registries at admission, post-procedure and before discharge.
RESULTS
Patients after TAVI presented a longer PR interval, a wider QRS, and a longer corrected QT, with a left deviation of QRS axis and T waves; reversible changes that tended to correct in the following days after TAVI. Complete atrioventricular block incidence was 2.9%. New-onset left bundle branch block (LBBB) incidence was 39%, although solved in almost half of patients before discharge.
CONCLUSIONS
TAVI was associated with different reversible electrocardiographic changes that suggest a transient impact on the conduction system. One of every five patients presented permanent LBBB after valve implant.