Fabrication of a 3D-Printed Interim Bite Splint for a Hemimandibulectomy Patient: A Case Report.

Sampat Saumil C, Kadam Ishan V, Kadam Ankita, Sahwal Kanchan S, Ingle Sangharsh

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Mandibular continuity defects can result in varying degrees of cosmetic disfigurement. Restoration of form and function may require surgical reconstruction of the affected area. While surgical reconstruction may improve the overall prognostic outcomes for the patient, the definitive prosthetic phase can commence only after a substantial time lag for adequate hard/soft tissue healing. This interim phase often challenges the patient's masticatory ability. The traditional reconstruction of hemimandibulectomy defects has its own limitations. This case report describes the fabrication of a 3D-printed bite splint for a patient with limited mouth opening and significant malocclusion due to surgical over-correction. The prosthesis given served as an appliance to improve the masticatory ability of the patient.

Для цитирования: Sampat Saumil C, Kadam Ishan V, Kadam Ankita, Sahwal Kanchan S, Ingle Sangharsh. Fabrication of a 3D-Printed Interim Bite Splint for a Hemimandibulectomy Patient: A Case Report.. Cureus. 2024. DOI: 10.7759/cureus.64120.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.