BACKGROUND

Female patients are underrepresented in cardiac resynchronization therapy (CRT) trials, although they show better CRT response compared to males and at shorter QRS durations. We hypothesized that differences in left bundle branch block (LBBB) characteristics and mechanical dyssynchrony might explain this gender disparity.

METHODS

Patients presenting with true LBBB-morphology (including mid-QRS notching) on surface electrocardiograms (ECG) were selected. LBBB QRS duration (QRSDLBBB) was measured automatically on the ECG. Left ventricular dimensions were assessed by two-dimensional echocardiography. Mechanical dyssynchrony was assessed by the presence of septal flash (SF) on echocardiography.

RESULTS

The study enrolled 1037 patients (428 females). Female LBBB patients had smaller QRSDLBBB compared to male LBBB patients (142 [22]ms versus 156 [24]ms, p<0.001). In a multivariate analysis, sex and left ventricular end-diastolic diameter (LVEDD) were independent predictors of QRSDLBBB. QRSDLBBB can be corrected for sex and LVEDD using a simplified formula: corrected-QRSDLBBB=QRSDLBBB+0.5×(50-LVEDD)-10 (if male). SF was more prevalent in females compared to males (60% versus 43%, p<0.001). Women revealed significantly more SF in narrow QRSDLBBB groups compared to men: 65% versus 13% (p<0.001) with QRSDLBBB 120-129ms, 66% versus 18% (p<0.001) with QRSDLBBB 130-139ms and 63% versus 31% (p<0.001) with QRSDLBBB 140-149ms. At QRSDLBBB>150ms, there were no differences in SF prevalence between females and males.

CONCLUSION

Female patients show true LBBB morphology at shorter QRSD and have more frequent mechanical dyssynchrony at shorter QRSD compared to males. This might explain the better CRT response rates at shorter QRSD in females.

Для цитирования: De Pooter Jan, Kamoen Victor, El Haddad Milad, Stroobandt Roland, De Buyzere Marc, Jordaens Luc, Timmermans Frank. Gender differences in electro-mechanical characteristics of left bundle branch block: Potential implications for selection and response of cardiac resynchronization therapy.. International journal of cardiology. 2018. DOI: 10.1016/j.ijcard.2017.10.055.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.