Association between implantation depth assessed by computed tomography and new-onset conduction disturbances after transcatheter aortic valve implantation.

Almeida João Gonçalves, Ferreira Sara Moura, Fonseca Paulo, Dias Tiago, Guerreiro Cláudio, Barbosa Ana Raquel, Teixeira Pedro, Carvalho Mónica, Ferreira Wilson, Ferreira Nuno Dias, Oliveira Marco, Gonçalves Helena, Braga Pedro, Ribeiro José, Primo João, Ribeiro Vasco Gama

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic valve replacement (TAVR) is often associated with intraventricular conduction disturbances. We aimed to determine the association between implantation depth assessed by multidetector computed tomography (MDCT) and new-onset conduction abnormalities after TAVR.

METHODS

Retrospective single-center study including patients consecutively submitted to TAVR, between August/2007 and October/2016, who underwent routine MDCT 3 months after the procedure. The endpoint of conduction disturbances included permanent pacemaker implantation and/or new-onset left bundle-branch block. Implantation depth was determined as the distance between the ventricular end of the prothesis and the native ring, at the level of the non-coronary cusp.

RESULTS

138 patients were included (female gender 52.2%, mean age 78.7 ± 6.9 years). The EuroSCORE II was 4.0 ± 3.9% and 57.2% were treated with self-expanding prosthesis. The endpoint of conduction abnormalities was found in 45.7% (n = 63). The implantation depth was greater in the group with conduction disturbances (7.7 vs 6.4 mm, p = 0.006). Chronic obstructive pulmonary disease, oversizing and implantation depth were independent predictors of conduction abnormalities. Implantation depth had an AUC of 0.64 (p = 0.004) for the prediction of conduction abnormalities and a cut-off value of 7.1 mm predicted the composed endpoint with a sensitivity and specificity of 65% and 70%, respectively.

CONCLUSIONS

Implantation depth assessed by MDCT is associated with new-onset conduction disturbances after TAVR. In patients with conduction abnormalities, which do not qualify for the immediate implantation of pacemaker, the assessment of implantation depth by MDCT may be an additional marker of risk to aid decision-making.

Для цитирования: Almeida João Gonçalves, Ferreira Sara Moura, Fonseca Paulo, Dias Tiago, Guerreiro Cláudio, Barbosa Ana Raquel, Teixeira Pedro, Carvalho Mónica, Ferreira Wilson, Ferreira Nuno Dias, Oliveira Marco, Gonçalves Helena, Braga Pedro, Ribeiro José, Primo João, Ribeiro Vasco Gama. Association between implantation depth assessed by computed tomography and new-onset conduction disturbances after transcatheter aortic valve implantation.. Journal of cardiovascular computed tomography. 2017. DOI: 10.1016/j.jcct.2017.08.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.