MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/14992027.2015.1094188

Медицинская библиотека · International journal of audiology · 2015

Ototoxicity (cochleotoxicity) classifications: A review.

Crundwell Gemma, Gomersall Phil, Baguley David M

СтатьяОбзорПеревод в очереди

Аннотация

OBJECTIVE

Drug-mediated ototoxicity, specifically cochleotoxicity, is a concern for patients receiving medications for the treatment of serious illness. A number of classification schemes exist, most of which are based on pure-tone audiometry, in order to assist non-audiological/non-otological specialists in the identification and monitoring of iatrogenic hearing loss. This review identifies the primary classification systems used in cochleototoxicity monitoring. By bringing together classifications published in discipline-specific literature, the paper aims to increase awareness of their relative strengths and limitations in the assessment and monitoring of ototoxic hearing loss and to indicate how future classification systems may improve upon the status-quo.

DESIGN

Literature review.

STUDY SAMPLE: PubMed identified 4878 articles containing the search term ototox*.

RESULTS

A systematic search identified 13 key classification systems. Cochleotoxicity classification systems can be divided into those which focus on hearing change from a baseline audiogram and those that focus on the functional impact of the hearing loss.

CONCLUSIONS

Common weaknesses of these grading scales included a lack of sensitivity to small adverse changes in hearing thresholds, a lack of high-frequency audiometry (>8 kHz), and lack of indication of which changes are likely to be clinically significant for communication and quality of life.

Для цитирования: Crundwell Gemma, Gomersall Phil, Baguley David M. Ototoxicity (cochleotoxicity) classifications: A review.. International journal of audiology. 2015. DOI: 10.3109/14992027.2015.1094188.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.