MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.msksp.2023.102738

Медицинская библиотека · Musculoskeletal science & practice · 2023

Physical testing in patients with acute whiplash-associated disorders: A within session test-retest reliability study.

Anarte-Lazo E, Rodriguez-Blanco C, Falla D, Bernal-Utrera C

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

People with whiplash-associated disorders (WAD) commonly present with a variety of physical impairments. However, the reliability of physical tests has not been established for patients with acute WAD.

OBJECTIVE

To assess test-retest reliability of different physical tests in acute WAD.

DESIGN

Intra-rater test-retest reliability.

METHODS

Patients with acute WAD were recruited. Physical tests were used to evaluate articular, muscular and neural systems in two blocks of measurements separated by 10 min. Bland-Altman plots were performed to assess intrarater agreement, which included calculation of the mean difference (d) between rates, the 95% CI for d, the standard deviation of the differences and the 95% limits of agreement. Reliability was calculated via the standard error of measurement, the minimal detectable change, percent of agreement, the intraclass-correlation coefficient, and kappa coefficient.

RESULTS

47 patients participated. Test-retest reliability was excellent or good for almost all measures, except for extension ROM, ULTT for the radial nerve, and active cervical extension and upper cervical rotation performed in 4-point kneeling, which presented moderate reliability. Systematic bias was found in cervical ROM in flexion, left and right lateral-flexion, left and right rotation; left ULTT for radial nerve; right trapezius, suboccipitalis and temporalis muscles, left temporalis; C3, both sides of C1-C2, left C3-C4.

CONCLUSION

The majority of physical tests achieved good or excellent test-retest intra-rater reliability when tested in patients with acute WAD. Findings must be considered with caution for those tests which demonstrated systematic bias. Additional research is warranted to evaluate inter-rater reliability.

Для цитирования: Anarte-Lazo E, Rodriguez-Blanco C, Falla D, Bernal-Utrera C. Physical testing in patients with acute whiplash-associated disorders: A within session test-retest reliability study.. Musculoskeletal science & practice. 2023. DOI: 10.1016/j.msksp.2023.102738.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.