MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heartjnl-2012-302895

Медицинская библиотека · Heart (British Cardiac Society) · 2013

Operator exposure to x-ray in left and right radial access during percutaneous coronary procedures: OPERA randomised study.

Dominici Marcello, Diletti Roberto, Milici Caterina, Bock Carlo, Placanica Attilio, D'Alessandro Gianluigi, Arrivi Alessio, Italiani Marco, Buono Eduardo, Boschetti Enrico

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

Left radial access (LRA) and right radial access (RRA) have been shown to be safe and effective for coronary arteries catheterisation. However, the differences between the two approaches in terms of radiation exposure are still unclear. The aim of the present investigation is to evaluate in a randomised study, the dose of radiation absorbed by operators using either LRA or RRA.

DESIGN

Randomised, prospective, double arm, single centre study.

SETTING

University Hospital.

PATIENTS: Male or female subjects with stable, unstable angina and silent ischaemia.

INTERVENTIONS: The present study is a comparison of LRA and RRA for coronary artery catheterisation in terms of operators' radiation exposure.

MAIN OUTCOME MEASURES: The primary outcome measure was the radiation dose absorbed by operators; secondary outcome measures were fluoroscopy time, dose-area product and contrast delivered.

RESULTS

A total of 413 patients were enrolled; 209 were randomly selected to undergo diagnostic procedures with RRA and 204 with LRA. The operator's radiation exposure was significantly lower in the left radial group (LRA 33±37 μSv vs RRA 44±32 μSv, p=0.04). No significant differences were observed in  fluoroscopy time (LRA 349±231s vs RRA 370±246 s p=0.09) and dose-area product (LRA 7011.42±3617.30 μGym(2) vs RRA 7382.38±5226.61 μGym(2), p=0.80), even though in both there was a trend towards a lower level in the LRA. No differences were observed in contrast medium delivered (LRA 89.92±32.55 ml vs RRA 88.88±35.35 ml, p=0.45).

CONCLUSIONS

The LRA was associated in the present report with a lower radiation dose absorbed by the operator during coronary angiography.

Для цитирования: Dominici Marcello, Diletti Roberto, Milici Caterina, Bock Carlo, Placanica Attilio, D'Alessandro Gianluigi, Arrivi Alessio, Italiani Marco, Buono Eduardo, Boschetti Enrico. Operator exposure to x-ray in left and right radial access during percutaneous coronary procedures: OPERA randomised study.. Heart (British Cardiac Society). 2013. DOI: 10.1136/heartjnl-2012-302895.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.