Dual-phase 99mTc-MIBI scintigraphy to assess calcimimetic effect in patients on haemodialysis with secondary hyperparathyroidism.

Fuster David, Torregrosa José-Vicente, Domenech Beatriz, Solà Oriol, Martín Gloria, Casellas Joan, Setoain Xavier, Muxí Africa, Pons Francesca

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the effect of calcimimetics with 99mTc-methoxy-isobutyl-isonitrile (MIBI) parathyroid scintigraphy in secondary hyperparathyroidism.

METHODS

This prospective study included 30 consecutive haemodialysis patients with inadequately controlled secondary hyperparathyroidism despite standard medical treatment. Patients were given a single daily oral dose of 30 mg of cinacalcet. A baseline and 1-year follow-up dual-phase 99mTc-MIBI scintigraphy were performed. 99mTc-MIBI uptake in each parathyroid gland was graded on a semiquantitative scale (scoring 0-3).

RESULTS

Twenty-one of the 30 patients responded to cinacalcet (70%). Abnormal positive glands were identified by 99mTc-MIBI scintigraphy in 27 out of 30 patients (53 glands). The sensitivity and specificity of 99mTc-MIBI in detecting cinacalcet response were 90 and 89%, respectively. The mean baseline and posttreatment grades of 99mTc-MIBI uptake were 2.9 ± 1.8 and 1.1 ± 1.2 (P < 0.0001) in the responder group and 3.1 ± 2.1 and 3.9 ± 2.2 (P = ns) in the nonresponder group.

CONCLUSION

99mTc-MIBI scintigraphy is useful in monitoring the response to calcimimetics in secondary hyperparathyroidism.

Для цитирования: Fuster David, Torregrosa José-Vicente, Domenech Beatriz, Solà Oriol, Martín Gloria, Casellas Joan, Setoain Xavier, Muxí Africa, Pons Francesca. Dual-phase 99mTc-MIBI scintigraphy to assess calcimimetic effect in patients on haemodialysis with secondary hyperparathyroidism.. Nuclear medicine communications. 2009. DOI: 10.1097/mnm.0b013e3283305df6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.