MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1677/jme-08-0164

Медицинская библиотека · Journal of molecular endocrinology · 2009

Calcium-sensing receptor mutations and denaturing high performance liquid chromatography.

Cole David E C, Yun Francisco H J, Wong Betty Y L, Shuen Andrew Y, Booth Ronald A, Scillitani Alfredo, Pidasheva Svetlana, Zhou Xiang, Canaff Lucie, Hendy Geoffrey N

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The calcium-sensing receptor (CASR), a plasma membrane G-protein-coupled receptor, is expressed in parathyroid gland and kidney, and controls systemic calcium homeostasis. Inactivating CASR mutations are associated with familial hypocalciuric hypercalcemia (FHH) and neonatal severe hyperparathyroidism, and activating mutations cause autosomal dominant hypocalcemia (ADH). CASR mutation identification plays an important role in the clinical management of mineral metabolism disorders. We describe here a high-throughput method using screening with denaturing high performance liquid chromatography (DHPLC) to initially interrogate 12 amplicons covering translated exons and exon/intron boundaries, followed by sequencing of any amplicon with a modified melting curve relative to wild type, and direct sequencing of a 13th amplicon encoding the COOH-terminal tail to distinguish causative mutations from three common missense single nucleotide polymorphisms. A blinded analysis of 32 positive controls representing mutations throughout the CASR sequence, as well as 22 negative controls, yielded a concordance rate of 100%. We report eight novel and five recurrent FHH mutations, along with six novel and two recurrent ADH mutations. Thus, DHPLC provides a rapid and effective means to screen for CASR mutations.

Для цитирования: Cole David E C, Yun Francisco H J, Wong Betty Y L, Shuen Andrew Y, Booth Ronald A, Scillitani Alfredo, Pidasheva Svetlana, Zhou Xiang, Canaff Lucie, Hendy Geoffrey N. Calcium-sensing receptor mutations and denaturing high performance liquid chromatography.. Journal of molecular endocrinology. 2009. DOI: 10.1677/jme-08-0164.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.